![Sub-Zero VI42B Service Manual Download Page 29](http://html1.mh-extra.com/html/sub-zero/vi42b/vi42b_service-manual_1388138029.webp)
Page 29
V-Series Cooktop Hoods
V-Series Cooktop Hoods
Wiring Diagrams
6-2
#825309 - Revision A - August, 2014
Basic Wiring
115 VAC comes in through the junction box then plugs into the Electrical Box. It is wired to the Power Board with a
three wire harness.
From the Power Board 115 VAC is sent back to the Electrical Box to the Terminal Block where the Internal, Remote
or Inline Blower is connected.
Voltage goes through the Ribbon Cable Harness from the Power Board through the Easy Cube and connects to the
Ribbon Cable from the Hood Body to provide power to the Touch Control. A signal back to the Power Board returns
through the same ribbon cable.
115 VAC is provided to the Light Transformer on the primary side of the Transformer. The Transformer converts the
115 VAC to 12 VDC and provides power to the LED Assemblies through a two wire harness that has a connector in
the Easy Cube. The Hood Body has a two wire harness from the LED Assemblies that connects to the harness in
the Easy Cube.