Page 14
2-10
#825309 - Revision A - August, 2014
V-Series Cooktop Hoods
V-Series Cooktop Hoods
Wall Hood Mounting
If an Internal Blower is being installed, install Internal
Blower prior to mounting the Hood.
1. Mark center line of hood installation. Using the
information in Figure 5 and the Chart below, mark
hole locations for mounting brackets. Additional
wall framing is recommended in this area.
a. Position two mounting brackets for chimney
flue, then install using two mounting screws
per bracket.
b. Install the Easy Cube mounting screws so
there is approximately 1/4” gap between the
screw head and wall.
Note:
If wall framing is not available, use of wall
anchors is recommended.
9
1/8
"
(232)
A
(433)
(19)
17
1/16
"
3/4
"
BOTTOM OF HOOD
CEILING
B
Figure 5. Bracket Mounting Location
Hood
Black
Glass
Stainless
Dimension “A”
12-3/4”
12-9/16”
16-3/8”
Dimension “B”
31-3/8” to 41-1/2”
31-3/8” to 41-1/2”
34-3/4” to 45-3/8”
Mounting
Mounting
Tab
Tab
Leveling
Leveling
Screw
Screw
Figure 6. Easy Cube Mounting.
2. Place the mounting tabs of the Easy Cube over the
mounting screws. Use leveling adjustment screws
to ensure hood is level. (See Figure 6)
3. Install Upper Chimney to Chimney Bracket.
4. Place Lower Chimney over Upper Chimney and
rest the Lower Chimney on the Hood Body. Fasten
two screw to the Easy Cube.