![Sub-Zero 424FS/G-2 Service Manual Download Page 47](http://html1.mh-extra.com/html/sub-zero/424fs-g-2/424fs-g-2_service-manual_1388562047.webp)
Page 47
Wine Storage
Wine Storage
(400-
(400-
2
2
)
)
Series
Series
Electronic Control System
3-31
#3758410 - Revision C - May, 2014
Monitor Compressor Run Duration, Displays If Service is Needed
The microprocessor observes the state of the compressor relay to determine the length of compressor run time (See
Figure 3-57). If the compressor runs 100% (4 hours), an error code is logged (EC 50), and defrost will be initiated,
but SERVICE will not flash.
If several 100% compressor run periods occur, and a drawer is not opened during the last excessive compressor run
period, and the temperature in the zone is not able to fall half way between set-point and low off-set, then SERVICE
will flash (See Figure 3-58).
NOTE:
To clear an error code, the problem must be corrected, then the Alarm ON/OFF key pressed for fifteen (15)
seconds. Failure to clear an error code will cause SERVICE to display constant.
NOTE:
If the unit is ever switched OFF then immediately back ON, the compressor will not energize for at least 3
minutes. This 3 minute minimum OFF time is used to protect the compressor and its electricals.
Figure 3-58. Service Flashing if several 100% compressor run periods occurred, a drawer was not opened
during last excessive run period, and temperature is not able to fall half way between set point & low off-set.
UNIT
REFRIGERATOR
ON/OFF
ON/OFF
WARMER
COLDER
SERVICE
Figure 3-57. Signal Trace Schematic - Compressor Run
115 VOLTS
60 CYCLES
HIGH VOLTAGE
L1
STARTING RELAY
COMPRESSOR
COMPRESSOR
PROTECTOR
OVERLOAD
NEUT
3
1
5
6
4
DPDT RELAY
BOARD
MAIN
BLACK
PURPLE
BLUE
WHITE
NEUTRAL WHITE
NEUTRAL WHITE
RED
PURPLE
ORANGE
BLACK
RED
YELLOW
LOWER DRAWER LIGHTS
CONDENSER FAN MOTOR
EVAPORATOR FAN MOTOR
TOP DRAWER LIGHTS
M
M
2000 Ω
MULLION HEATER
NEUTRAL WHITE
M
ORANGE
ORANGE
DOOR SWITCH
DOOR SWITCH
P4
J5
J4
J6
J3
P2
P1
P3
J2
Compressor relay closed, allowing 115 Volts AC to
compressor. This is observe by microprocessor.