![Sub-Zero 424FS/G-2 Service Manual Download Page 25](http://html1.mh-extra.com/html/sub-zero/424fs-g-2/424fs-g-2_service-manual_1388562025.webp)
Page 25
Wine Storage
Wine Storage
(400-
(400-
2
2
)
)
Series
Series
Electronic Control System
3-9
#3758410 - Revision C - May, 2014
FUNCTION OF THE WINE STORAGE ELECTRONIC CONTROL SYSTEM
The following pages explain monitoring, regulating and controlling functions of the electronic control system. In most
cases signal traces for the 424-2 wiring schematic are used to show current flow for functions being explained.
TO AVOID ELECTRIC SHOCK, POWER TO THE UNIT MUST BE DISCONNECTED WHENEVER ACCESSING
AND/OR REMOVING COMPONENTS POWERED BY ELECTRICITY OR COMPONENTS NEAR OTHER ELEC-
TRICAL COMPONENTS.
EVEN WHEN UNIT IS SWITCHED OFF, AC POWER IS STILL PRESENT AT THE CONTROL BOARD.
60 CYCLES
115 VOLTS
GREEN/YELLOW
J3
CONTROL
BOARD
BLACK
E3
14
E1
E2
WINE
J8
2
8
J1
J2
1
L1
OVERLOAD PROTECTOR
GRAY
WHITE
PINK
BROWN
TAN
ORANGE
ORANGE
PINK
STARTING RELAY
CONDENSER FAN MOTOR
COMPRESSOR
COMPRESSOR
EVAPORATOR FAN MOTORS
AWECO REF VALVE
LIGHTS
680 Ω
LOWER
LIGHTS
NEUT
WHITE
UPPER
BLUE
BLUE
N.O.
N.O.
N.C.
PINK
BLUE
1
M
M
M
M
Supply Power to the Lighting System
When the unit is plugged in, a continuous 115 Volts AC is supplied to the lighting system, making it possible to ener-
gize the lights 100% of the time, even if the door is closed. (See Lighting System ON/OFF). The lighting system
can also be disabled for observance of certain religious days, (See Sabbath Mode). The illustration below shows
normal operation, with 115 Volts AC supplied to the unit. (See Figure 3-15)
ELECTRIC SHOCK HAZARD. 115 VOLTS AC IS STILL PRESENT AT THE CONTROL BOARD AND LIGHT
SWITCH WHEN LIGHTS ARE DISABLED.
Figure 3-15. Lighting System Signal Trace (Normal Operation)
NOTE: If display lighting is activated, power is sup-
plied to lights, bypassing light switch