Electronic Control System
Wine Storage
Wine Storage
(400-
(400-
2
2
)
)
Series
Series
3-30
#3758410 - Revision C - May, 2014
Regulate Zone Temperature and Fan-Assisted Off-Cycle Defrost
When the thermistor in the refrigerator compartment reaches high off-set temperature, calling for cooling, the evapo-
rator fan is energized, but the compressor is not allowed to run until the thermistor on the evaporator reaches 38°F
(3°C). (See Figure 3-56)
If either drawer is opened while the evaporator fan is operating, the microprocessor will detect the power signal to
the lights and cut power to the fan.
Though compartment air temperatures will fluctuate, the LCD will only display average temperature.
NOTE:
If compartment temperature exceeds either high or low offset (Ex: drawer is left open), temperature display
will change by one degree per minute.
NOTE:
If refrigerator compartment thermistor is faulty, compressor operation defaults to 20 minutes ON, 40 minutes
OFF cycling, EE appears in left of LCD, SERVICE will flash and Error Code 05 will be logged.
NOTE:
If evaporator thermistor is faulty, the compressor will not energize until zone air temperature exceeds high
offset by 5°F (3°C). SERVICE flashes and Error Code 06 is logged.
NOTE:
When in Sabbath Mode, the refrigerator compartment thermistor still controls compressor operation, except
there is a random 15 to 25 second delay before the compressor is energized.
Figure 3-56. Signal Trace - Regulate Refrigerator Zone Temperature
115 VOLTS
60 CYCLES
LOW VOLTAGE
HIGH VOLTAGE
L1
STARTING RELAY
COMPRESSOR
COMPRESSOR
PROTECTOR
OVERLOAD
NEUT
3
1
5
6
4
DPDT RELAY
BOARD
MAIN
BLACK
PURPLE
BLUE
WHITE
BLUE
PURPLE
BOARD
MAIN
BLACK
WHITE
BLUE
RED
WHITE
BLACK
ORANGE
YELLOW
NEUTRAL WHITE
THERMISTER
CONTROL
DRAWER
BLUE W/ WHITE
CABINET
BLUE W/ WHITE
NEUTRAL WHITE
RED
PURPLE
ORANGE
BLACK
RED
YELLOW
BLUE /W BLACK
THERMISTER
EVAPORATOR
BLUE /W BLACK
LOWER DRAWER LIGHTS
CONDENSER FAN MOTOR
EVAPORATOR FAN MOTOR
TOP DRAWER LIGHTS
M
M
2000 Ω
MULLION HEATER
NEUTRAL WHITE
M
ORANGE
ORANGE
DOOR SWITCH
DOOR SWITCH
P4
J5
J4
J6
J3
P2
P1
P3
J2
J4
J5
J3
J6
P1
P2
J2
P4
P3
1. Thermistor at high off-set
temp. calling for cooling.
2. No Power
to lights.
5. Compressor
energized.
4. Evap Thermistor
above 38°F (3°C).
3. Evap fan energized.