Style selections 0293808 Manual Download Page 14

14

CAUTION

: Two gas line installations at the same time is forbidden. Do not open the 

cover while the machine is running. 

Heater is pre-set at factory for propane gas; no changes are required for connecting to 

propane. Only a qualified installer or service technician can perform gas selection and 

connecting to gas supply.

 

CAUTION

: To avoid gas leakage at the inlet of regulator, a qualified installer or service 

 

technician must use steel or metal hex plug with sealant. Overtightening of inlet gas line    

 

can cause a crack in the internal regulator.

For changing from propane to natural gas supply

1. Remove bottom screw from cover plate, (see Fig. 8), and rotate to expose gas 

selection valve.

2. For NATURAL GAS, press in knob using a flat screwdriver with a blade the width of a 

  quarter and turn knob clockwise 

 until the knob locks into the NG position (see Fig. 9).

3. Rotate and close cover over gas selection valve and reinstall screw.

4. Remove steel or metal hex plug (with wrench provided) from natural gas inlet of regulator    

  and install into LP inlet of regulator, use thread sealant to assure there are no leaks.

For changing from natural gas supply to propane supply

1. Remove bottom screw from cover plate, (see Fig. 8), and rotate to expose gas selection  

  valve.

2. For PROPANE GAS, press in knob using a flat screwdriver with a blade the width of a  

  quarter and turn knob counterclockwise 

 until the knob locks into the LP position 

  (see Fig. 10). Selection valve must be locked into either the LP position or the NG    

  position.

3. Rotate and close cover over gas selection valve and reinstall screw.

4. Remove steel or metal hex plug from LP gas inlet of regulator and install into NG inlet of  

  regulator, use thread sealant to assure there are no leaks.

Summary of Contents for 0293808

Page 1: ...e not prohibited by local codes This appliance is for use with the type of gas indicated on the rating plate only This appliance is not convertible for use with other gases This is an unvented gas fir...

Page 2: ...x 13 9 in Carton 40 94 in x 32 28 in x 17 32 in Weight lbs Stove 97 Shipping 104 Safety Information 3 Product Features 6 Air For Combustion and Ventilation 8 Installation 11 Installing Logs 17 Operat...

Page 3: ...influence of alcohol and those living in high altitudes NATURAL AND PROPANE LP GAS Natural and Propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas l...

Page 4: ...onditions 6 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white powder residue within burner box or on adja...

Page 5: ...ng and the heater burning manufacturing residues QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories...

Page 6: ...d plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale o...

Page 7: ...become a problem 1 Be sure the heater is the proper size for the application including adequate combustion air and circulation air 2 If there is high humidity a dehumidifier may be used to help lower...

Page 8: ...gate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are considered a pa...

Page 9: ...er logs ________ BTU hr Gas water heater 30 000 BTU hr Other gas appliances ___BTU hr Vent free heater 26 000 BTU hr Total ________________ BTU hr Total 56 000 BTU hr Do not include direct vent gas ap...

Page 10: ...if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Rework worksheet adding the space of the adjoining unconfined space The combined spaces must...

Page 11: ...amps etc in the air exist may cause walls discolored WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent f...

Page 12: ...able alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never connect heater to private non utility gas wells This gas is...

Page 13: ...e recommend that you install a sediment trap in a supply line as shown in Fig 7 Locate sediment trap where it is within reach for cleaning and not likely to freeze Install in the piping system between...

Page 14: ...of a quarter and turn knob clockwise until the knob locks into the NG position see Fig 9 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal hex plug with wr...

Page 15: ...15 Fig 10 Fig 9 Fig 8 NATURAL GAS PROPANE GAS PLUG NATURAL GAS PROPANE GAS PLUG...

Page 16: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig 11 2 Pressure supply...

Page 17: ...g 2 with the other end of log 5 placed on log 3 as shown 1 2 3 5 4 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this...

Page 18: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 19: ...ing ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob p...

Page 20: ...d pulling forward 3 Follow steps 1 through 5 under Lighting Instructions 4 With control knob in PILOT position strike match and hold near pilot Press in control knob pilot should light 5 Keep control...

Page 21: ...ame Pattern with Control Knob Set to High Flame 5 Fig 19 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 BURNER FLAME PATTERN Fig 18 shows a correct burner flame pattern Fig 19 sho...

Page 22: ...Repeat steps 3 and 4 Clean the pilot assembly also WARNING Failure to keep primary air openings of burners clean may result in sooting and property damage CAUTION You must keep control areas burner a...

Page 23: ...may blow through a drinking straw if compressed air is not available CABINET Air Passageways Use a vacuum cleaner or pressurized air and a small soft bristled brush to clean Exterior Use a soft cloth...

Page 24: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electro...

Page 25: ...orifice 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 22...

Page 26: ...r furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products H...

Page 27: ...Customer Service have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask...

Page 28: ...1 2 Piezo Ignitor PIMSC1 01 1 3 DF Regulator RV83FI 4 9 1 4 Gas Selection Valve YDF06 1 5 Rear Barrier ED200L7C 06 2 6 Mid Log Bracket AN LI200MV 202 1 7 Grill Assembly EB29600H 1 8 Door EL013 01B1 0...

Page 29: ...29 1 2 3 4 5 7 8 9 10 11 12 13 14 15 6...

Page 30: ...tity Shown to size AA ST4 8 Screw 2 3 8 in 2 BB 8 CC 12 DD Wall Anchor 2 ST4 Screw 1 3 8 in ST4 Screw 5 8 in PREPARATION Before beginning assembly of product make sure all parts are present Compare pa...

Page 31: ...screw 5 8 in CC as shown in Fig 1 Fig 1 Hardware Used CC ST4 Screw 5 8 in x 12 With the fireplace top panel assembled reattach the assembled top with the fireplace Fig 2 Hardware Used BB ST4 Screw 1 3...

Page 32: ...holes by pinching the anchor tabs together Hardware Used Wall Anchors x 2 4 Attach the triangular wood block to the holes drilled in step 4 with ST4 8 screw 2 3 8 in AA as shown in Fig 4 This block is...

Page 33: ...ccident misuse improper installation or by affixing accessories not produced by the manufacturer are the purchaser s responsibility The manufacturer assumes no responsibility whatsoever for installati...