Residual Hazards and Emergency Information
This unit was designed to reduce danger sources or situations to a minimum.
These dangers arise from improper use of the product or from failure to comply with installation
and operating instructions.
All personnel who work on or near the unit must be familiar with these instructions.
10.1
General safety provisions
All personnel charged with testing and maintaining the unit must be familiar with the following
safety regulations:
Danger signs must be easily visible in areas of potential danger.
A visual supervision service must be set up in danger areas.
Supervisors must keep constant contact with controllers.
Transit zones, doors and ladders placed near the area where the unit is located must never
be blocked.
Emergency exits must never be blocked.
Slippery areas that could be a potential risk for persons must be covered with anti-slip
materials.
Proper tools and suitable procedures must be used for every specific activity.
Test tools and equipment must be kept in good order.
Personnel must have in-depth knowledge of methods and procedures to apply in case of fire
(set up a fire extinguisher service in a handy position).
The following actions must be taken if a fire starts:
Switch off the electrical power supply to the component that is burning.
Switch off all fans so as to cut the oxygene supply.
Advise the appropriate department.
10.2
Hazards arising from the product coming into contact with things or persons
Danger point 1a) comes from movement by the fan. The grating mesh has a useful gap,
between wires, smaller than 10 mm. Particles with smaller dimensions could be ejected by
the fan blade.
Danger point 1b) comes from accidental contact with the heat exchanger since its aluminium
fins can have sharp edges.
10.3
Hazards arising from electrical faults
SAFETY STANDARDS FOR ELECTRICAL EQUIPMENT
Introduction
The causes of electrical risks are well known and it is not difficult to prevent these risks by
applying constant care and attention.
Assigned personnel must be informed regarding potential dangers and trained regarding safety
procedures in order to reduce the number of potential electrical accidents.
Summary of Contents for Tel-Air-2 Series
Page 2: ......
Page 27: ...E 0618 35A 27 TLD F 40 TLD F 60 TLD F 80 TLD F 40 TLD F 80...
Page 28: ...E 0618 35A 28 TLD F 90 TLD F A2 TLD F A4 TLD F 90 TLD F A4...
Page 29: ...E 0618 35A 29...
Page 30: ...E 0618 35A 30...
Page 31: ...E 0618 35A 31...
Page 37: ...E 0618 35A 37 Cut out TLF TLD 40 60 EXTERNAL OUTSIDE...
Page 38: ...E 0618 35A 38 Cut out FLOOR TLD 40 60 FRONT SIDE REAR SIDE...
Page 39: ...E 0618 35A 39 Cut out TLU 40 60 EXTERNAL OUTSIDE...
Page 40: ...E 0618 35A 40 Cut out TLF TLD 80 A4 EXTERNAL OUTSIDE...
Page 41: ...E 0618 35A 41 Cut out FLOOR TLD 80 A4 FRONT SIDE REAR SIDE...
Page 42: ...E 0618 35A 42 Cut out TLU 80 A4 EXTERNAL OUTSIDE...
Page 61: ...E 0618 35A 61...
Page 62: ...E 0618 35A 62...
Page 63: ...E 0618 35A 63...
Page 64: ...E 0618 35A 64...
Page 72: ......