BEFORE USING
Read all cautions and warnings to page 1 prior to install this equipment. Particularly, read the follow:
1) Disconnect power before lamp’s replacement or servicing (service personnel)
2) Do not open the lamp cover for 300 seconds after switching off
3) Wear gloves and goggles to re-lamping or to work inside the unit (service personnel)
4) The equipment must be connected to branch circuit having a circuit-breacker In=16A • Id=0.03A (230VAC)
5)
Make sure that the main voltage and frequency correspond to rated values on the data label, pict.1.
If is necessary set-up the red connector to the right position, pict.1a/1b
Before any operation on the fixture
a) Do not install the spot close to the heat sources. Do not lay the connection cable on the spot when it is warm.
b) This unit must be positioned as to allow its ventilation.
c) The unit must be positioned at least 1 m from walls or other flammable surfaces and minimum 5 meters to lighted objects.
-External surface temperature Ta 45°C:
• After 5 minutes work; Tc=75°C.
• Once the thermic balance has been obtained; Tc=100°C.
d) Replace the lamp when is exhausted (6000 h) to avoid bad peformances of the fixture or that the optic system is damaged by
the lamp explosion. It must be replaced if it has been damaged or thermally deformed
e) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
has been reduced, for example, by cracks or deep scratches.
f) In case of installation of the spot to a truss, check carefully that the fixture is fixed with a chain to both truss and unit.
g) Do not handle the spot by taking it by the head, but always by using the handles.
pict.1
230V
240V
230V
240V
WARNING
!
The equipment must be earthed.
IP 66 rate: to ensure the declared IP rate choose the correct size of the cables
(DMX cables: size form 3 to 6.5 mm - Main Power cables: size from 6 to 12 mm).
All the gaskets and the glass must be keeped in full working order.
If the fixture is not connected with DMX cables DON'T REMOVE the green protection.
pict.1a
pict.1b
CITYCOLOR400 art. 0302
CITYCOLOR400 art. 0302
®
SN
QC
230 V
; 2.24A; 50-60 Hz
AC
230 V
; 2.24A; 50-60 Hz
AC
Do not open for 300 seconds after the switching off.
Disconnect the unit from power before replacing the lamp or ser vicing
CAUTION:
Very hot lamp
• EXPLOSION HAZARD •
Ta 45°C
Tc 100°C
Ta 45°C
Tc 100°C
1m
IP 66
IP 66
LAMP CDM-T 150W G12
LAMP CDM-T 150W G12
T5A
T2A
MAIN FUSE
MAIN FUSE
INSIDE
ELEC. FUSE
ELEC. FUSE