background image

...15 ...

MOTORS BOARD

• POWER 30V Led On   
• +5V Led
• +320V Led
•+5V DMX Led
• DMX signal
       Led flashing: 

the DMX signal is operating on the board

       Led off: 

 

check the U1 (6N137) and the DMX connecting cable (from PCB PAN IP)

• STEPPER MOTOR channel not working: (i.e. YELLOW):
1)    Switch off the fixture and disconnect the YELLOW and CYAN cables
2)    Connect the YELLOW cable on the CYAN connector
3)    Switch on the fixture:
3a)  If the YELLOW motor works normally it is necessary to replace the U6 (L6219)
3b)  If the motor is still not working check with extreme attention the motor and the  interconnecting circuits (cables and    
       connectors). To check the cables and the motors you can measure the resistance as follows:
       between PIN 1 and PIN21 (on IC U6)r=~18ohm; between PIN 2 and PIN5 (on IC U6) r=~18ohm

• If the led +5V OPTODMX is off:
1)    Disconnect TO DISPLAY PCB PAN IP connector; if the led is on check PCB PAN IP
2)    Check U13 (78M05), L3, D6

• If the led +5V is off:
1)    Disconnect TO DISPLAY PCB PAN IP connector; if the led is on check PCB PAN IP
2)    Check D4, L2, U12

•If the led +28V is off:
1)    Check if the led +320V is on, if it is ok:
1a)  Check if U11 is in thermal drift 

(ATTENTION on the heat dissipator there is dangerous tension!!!!)

1b)  Check if U5, U6, U7, U8, U9 are in short-circuit.  Switch off  the fixture. Remove all the chips from the socket.
       Switch on the fixture: if the led is on, insert the chips one by one in the sockets to find out which is in short-circuit.
1c)  Check D3
1d)

  If all the operations described above have not given any positive result, change U11

2)    If the led +28V is off together with the led +320V
2a)  Check the MAIN POWER INPUT where you can measure the working voltage
2b)  Check the main fuse, if it is blown check VR1 (normally it has a resistance = 

). If it is in short circuit you must change it.

2c)  Check D1 (Bridge Rectifier), if it is ok check C65.
2d) 

If the fuse is still blown, change U11

Summary of Contents for CityColor400

Page 1: ...connection DMX signal connection fuses replacement page 4 Lamp installation replacement page 5 Control panel and configuration page 6 Use of the CityColor 400 page 6 DMX line and terminator page 8 Aut...

Page 2: ...TYPE LAMP 2 Maintain minimum distance of 0 5 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lighted objects of 5 0 meter 4 Replace fuses only with the specified t...

Page 3: ...208 230 240 50Hz On request 60Hz Rated power 500Va Rated current 2 2A 230V POWER FACTOR CORRECTOR built in cos 0 9 FUSES Lamp fuse 5 0A 250V delay time Electronic fuse 2 0A 250V delay time DIMENSION...

Page 4: ...mances of the fixture or that the optic system is damaged by the lamp explosion It must be replaced if it has been damaged or thermally deformed e The protection screens the lenses or the ultraviolet...

Page 5: ...R AND DMX CONNECTION 1 Disconnect power before lamp s replacement or servicing service personnel 1 Open the rear box cover The fixture can be equipped for 200 208 230 240Vac 50Hz main voltage pict 1a...

Page 6: ...pholder D and repeat this procedure for the other lamp pict 7 Do not touch the quarz bulb with fingers If this happenes clean the bulb before use with dry cloth and alcohol 7 Replace the two lateral r...

Page 7: ...h pre set selection slave LHrS lamp working hours FHrS fixture total working hours nChn channels number teSt auto test FLIP display inversion rSEt reset of the spot To select any of the given options...

Page 8: ...thout making any change press the MENU button rSEt Reset To run the complete reset press ENTER and keep it pressed up to when the display shows the flashing message r on reset on Once the reset proced...

Page 9: ...e DMX CONTROLLER OR LIGHT CONSOLE SIGNAL AMPLIFIER TERMINATION RESISTOR USE OF THE FIXTURE IN AUTO MODE A short list of the games can be found to page 11 Press the MENU button on the control panel up...

Page 10: ...GNMENT Here below you can find the complete list of DMX values ref page 7 The cables are the same as the DMX standard cable WARNING EXAMPLE OF CONNECTION AND SETTING OF 4 FIXTURE IN SYNCHRO MODE MASTE...

Page 11: ...ta White color mix sequence slow 30sec 07 All colors colr mix sequence slow 30sec 08 All colors White color mix sequence slow 30sec 09 All colors color mix sequence mid 20sec 10 All colors White color...

Page 12: ...l 37 Handle 38 DX lateral bracket 39 DX lateral steel plate 40 SX lateral steel plate 41 Head stop spacer 42 DX head stop 42 a SX head stop 43 Spacer 44 DMX control panel steel plate 45 DMX panel adhe...

Page 13: ...12 A BASE...

Page 14: ...13 B HEAD...

Page 15: ...TAGE PROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V MAIN POWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER MOT3 MAGENTA LED DMX SIGNAL LED 5V OPTO DMX U13 78M05 OPTO DMX TO...

Page 16: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 17: ...16 panip400 panipS400...

Page 18: ...ccip400 17...

Page 19: ...ccipS400 18...

Page 20: ...NOTE 19...

Reviews: