On the control panel of the CityColor (pict.8) you can find, besides the display, the leds and the buttons to use to set the spot.

LED 

• “DMX” led       flashing:              DMX input present
                            off:                       no DMX input 

• ”LAMP” led      flashing:              the lamp switching off is remotely controlled
                            off:                       lamp switched on

• ”DIMMER” led flashing:              the lamp is 33% dimmered
                            off:                       lamp switched on

BUTTONS

Four buttons are used to programme the spot:

• MENU              to select the programming options
• DOWN             to go backward in the selected options
• UP                    to go forward in the selected options
• ENTER             to confirm the selected options

DISPLAY

Shows the various menus and the selected options.

CONTROL PANEL

Addr

NChn

Test

FLIP

Rset

Mode

LHrs

FHrs

SUMMARY OF THE PROGRAMMING FUNCTIONS OF THE CITYCOLOR

About twenty seconds after the switching on, the number of the software version will be shown on the display  in “X_00” format. 
Afterwards the first of the eight available menus will appear:

Addr

    to assign the DMX-512 address

Mode

   DMX512 mode, master with pre-set selection, slave

LHrS

    lamp working hours

FHrS

    fixture total working hours

nChn

    channels number

teSt

      auto-test

FLIP

     display inversion

rSEt

     reset of the spot

To select any of the given options, press the MENU button up to when the required one is shown. 

Addr

 (Address)

To visualise the DMX address press ENTER.
To modify the address press Down and Up buttons and, once the required address has been selected, press  and keep ENTER pressed 
up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). To go back to 
the options without making any change, press the MENU button. 

Mode

 (Mode)

To visualise this mode press ENTER.
Use Down and Up buttons to change the mode and, once the required one has been selected, press and keep ENTER pressed up 
to when the display stops flashing (it flashes to indicate that the selected option is dif fer ent from the pre-set one). The available 
op tions are: no (normal) for the functioning in DMX reception; Pr01…Pr15 (pre-set 01…15) for the master functioning  with the re-
 spec tive game, SL (slave) for the func tion ing as slave. To go back to the op tions with out any change, press the MENU but ton.

Summary of Contents for CityColor400

Page 1: ...connection DMX signal connection fuses replacement page 4 Lamp installation replacement page 5 Control panel and configuration page 6 Use of the CityColor 400 page 6 DMX line and terminator page 8 Aut...

Page 2: ...TYPE LAMP 2 Maintain minimum distance of 0 5 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lighted objects of 5 0 meter 4 Replace fuses only with the specified t...

Page 3: ...208 230 240 50Hz On request 60Hz Rated power 500Va Rated current 2 2A 230V POWER FACTOR CORRECTOR built in cos 0 9 FUSES Lamp fuse 5 0A 250V delay time Electronic fuse 2 0A 250V delay time DIMENSION...

Page 4: ...mances of the fixture or that the optic system is damaged by the lamp explosion It must be replaced if it has been damaged or thermally deformed e The protection screens the lenses or the ultraviolet...

Page 5: ...R AND DMX CONNECTION 1 Disconnect power before lamp s replacement or servicing service personnel 1 Open the rear box cover The fixture can be equipped for 200 208 230 240Vac 50Hz main voltage pict 1a...

Page 6: ...pholder D and repeat this procedure for the other lamp pict 7 Do not touch the quarz bulb with fingers If this happenes clean the bulb before use with dry cloth and alcohol 7 Replace the two lateral r...

Page 7: ...h pre set selection slave LHrS lamp working hours FHrS fixture total working hours nChn channels number teSt auto test FLIP display inversion rSEt reset of the spot To select any of the given options...

Page 8: ...thout making any change press the MENU button rSEt Reset To run the complete reset press ENTER and keep it pressed up to when the display shows the flashing message r on reset on Once the reset proced...

Page 9: ...e DMX CONTROLLER OR LIGHT CONSOLE SIGNAL AMPLIFIER TERMINATION RESISTOR USE OF THE FIXTURE IN AUTO MODE A short list of the games can be found to page 11 Press the MENU button on the control panel up...

Page 10: ...GNMENT Here below you can find the complete list of DMX values ref page 7 The cables are the same as the DMX standard cable WARNING EXAMPLE OF CONNECTION AND SETTING OF 4 FIXTURE IN SYNCHRO MODE MASTE...

Page 11: ...ta White color mix sequence slow 30sec 07 All colors colr mix sequence slow 30sec 08 All colors White color mix sequence slow 30sec 09 All colors color mix sequence mid 20sec 10 All colors White color...

Page 12: ...l 37 Handle 38 DX lateral bracket 39 DX lateral steel plate 40 SX lateral steel plate 41 Head stop spacer 42 DX head stop 42 a SX head stop 43 Spacer 44 DMX control panel steel plate 45 DMX panel adhe...

Page 13: ...12 A BASE...

Page 14: ...13 B HEAD...

Page 15: ...TAGE PROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V MAIN POWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER MOT3 MAGENTA LED DMX SIGNAL LED 5V OPTO DMX U13 78M05 OPTO DMX TO...

Page 16: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 17: ...16 panip400 panipS400...

Page 18: ...ccip400 17...

Page 19: ...ccipS400 18...

Page 20: ...NOTE 19...

Reviews: