Stübbe PTM C2 Series Original Operating Manual Download Page 8

Appendix

8

Troubleshooting

WARNING

Risk of injury and poisoning due to hazardous media liq-
uids!

Use personal protective equipment when carrying out any
work on the device.

Error

Possible cause

Corrective action

Medium is leaking
out of the

fl

ange

Pre-tension of the
O-ring too small

Retighten
union nut by
hand.

Tab. 4

Troubleshooting

9

Appendix

9.1

Technical speci

fi

cations

Technical data (

Data sheet).

9.2

Dimensions

Dimensions (

Data sheet).

9.3

Plug assignment

2

3

4

1

Fig. 3

Connection diagram

1

Signal (+)

2

Signal (-)

3

n.c.

4

n.c.

8

PTM C2

BA-2016.11.24 EN

300 196

Summary of Contents for PTM C2 Series

Page 1: ...No 300 196 TR MA DE Rev002 ASV St bbe GmbH Co KG Hollwieser Strasse 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 Email contact asv stuebbe de Internet www asv stuebbe com We res...

Page 2: ...3 Storage 5 4 4 Disposal 6 5 Installation and connection 6 5 1 Check operating conditions 6 5 2 Installing device in the process pipework 6 5 3 Performing the hydrostatic test 6 5 4 Electrical connect...

Page 3: ...and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance Guide Chemical resistance of the materials used www asv stuebbe...

Page 4: ...d Make personal protective equipment available Qualified personnel Make sure all personnel tasked with work on the device have read and understood this manual and all other appli cable documents espec...

Page 5: ...4 1 Unpacking and inspection on delivery 1 Unpack the device when received and inspect it for trans port damage and completeness 2 Check that the information on the type plate agrees with the order de...

Page 6: ...against unintentional opening with shut off values Avoidance of medium buildup Select installation location so that no build up or crystalliza tion is possible WARNING Risk of injury and poisoning due...

Page 7: ...again Provide warning of maintenance and repair work and set up warning signs 7 1 Servicing Interval Action As necessary Clean device with a damp cloth Six monthly Visual and function check Normal ope...

Page 8: ...Possible cause Corrective action Medium is leaking out of the flange Pre tension of the O ring too small Retighten union nut by hand Tab 4 Troubleshooting 9 Appendix 9 1 Technical specifications Tech...

Reviews: