Stübbe PTM C2 Series Original Operating Manual Download Page 4

General safety instructions

2

General safety instructions

The manufacturer accepts no liability for damages caused
by disregarding any of the documentation.

2.1

Intended use

The device allows pressure in a liquid medium to be measured.

Device must only be used for measuring pressure in liquid
media.

Only use the device with suitable media
(

resistance lists).

Adhere to the operating limits

(

9.1 Technical speci

fi

ca-

tions, Page 8).

2.2

General safety instructions

Observe the following regulations before carrying out any
work.

2.2.1

Obligations of the operating company

Safety-conscious operation

Only operate the device if it is in perfect technical condition
and only use it as intended, staying aware of safety and
risks, and in adherence to the instructions in this manual.

Ensure that the following safety aspects are observed and
monitored:

Intended use

Statutory or other safety and accident-prevention reg-
ulations

Safety regulations governing the handling of haz-
ardous substances

Applicable standards and guidelines in the country
where the pump is operated

Make personal protective equipment available.

Quali

fi

ed personnel

Make sure all personnel tasked with work on the device
have read and understood this manual and all other appli-
cable documents, especially the safety, maintenance and
repair information, before they start any work.

Organize responsibilities, areas of competence and the
supervision of personnel.

The following work should be carried out by specialist tech-
nicians only:

Installation, repair and maintenance work

Work on the electrical system

Make sure that trainee personnel only work on the device
under supervision of specialist technicians.

2.2.2

Obligations of personnel

Only complete work on the device if the following requirements
are met:

System is empty

System has been

fl

ushed

System is depressurized

System has cooled down

System is secured against being switched back on again

Do not make any modi

fi

cations to the device.

2.3

Speci

fi

c hazards

2.3.1

Hazardous media

When handling hazardous media, observe the safety reg-
ulations for the handling of hazardous substances.

Use personal protective equipment for all work on the
device.

Collect leaking pumped liquid and residues in a safe man-
ner and dispose of in accordance with environmental reg-
ulations.

4

PTM C2

BA-2016.11.24 EN

300 196

Summary of Contents for PTM C2 Series

Page 1: ...No 300 196 TR MA DE Rev002 ASV St bbe GmbH Co KG Hollwieser Strasse 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 Email contact asv stuebbe de Internet www asv stuebbe com We res...

Page 2: ...3 Storage 5 4 4 Disposal 6 5 Installation and connection 6 5 1 Check operating conditions 6 5 2 Installing device in the process pipework 6 5 3 Performing the hydrostatic test 6 5 4 Electrical connect...

Page 3: ...and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance Guide Chemical resistance of the materials used www asv stuebbe...

Page 4: ...d Make personal protective equipment available Qualified personnel Make sure all personnel tasked with work on the device have read and understood this manual and all other appli cable documents espec...

Page 5: ...4 1 Unpacking and inspection on delivery 1 Unpack the device when received and inspect it for trans port damage and completeness 2 Check that the information on the type plate agrees with the order de...

Page 6: ...against unintentional opening with shut off values Avoidance of medium buildup Select installation location so that no build up or crystalliza tion is possible WARNING Risk of injury and poisoning due...

Page 7: ...again Provide warning of maintenance and repair work and set up warning signs 7 1 Servicing Interval Action As necessary Clean device with a damp cloth Six monthly Visual and function check Normal ope...

Page 8: ...Possible cause Corrective action Medium is leaking out of the flange Pre tension of the O ring too small Retighten union nut by hand Tab 4 Troubleshooting 9 Appendix 9 1 Technical specifications Tech...

Reviews: