- 19 -
Cont ...
5.22
SA - Technical assistance settings
To enter password is required contact PumpAssist for assistance on
+44 (0) 800 31 969 80.
No
Description
Factory
settings
Modifications
Note
SA01
SA02
SA03
Pressure PID (Proportional gain)
2.8
SA04
Pressure PID (Integral time constant)
5.5
SA05
Pressure PID (Derivative time constant)
5.0
SA06
Min. run frequency
(Hz)
30
SA07
Max. frequency
(Hz)
60
SA08
Set point pressure step up
(bar)
0.3
SA09
Pressure step up time
(s)
3
SA010
Pressure step up ramp
(bar/s)
0.3
SA011
Set point control ramp
(bar/s)
0.4
SA012
Carrier frequency
7010
SA013
Singlephase starting requency
(Hz)
80
SA014
Singlephase starting voltage
(V)
195
SA015
Nominal voltage
(V)
220
5.23
MAn - Fixed speed mode activation
To enter password is required contact PumpAssist for assistance on
+44 (0) 800 31 969 80.
No
Description
Factory
settings
Modifications
Note
MAn1
Fixed speed mode activation
oFF
MAn2
Working frequency [MAn2
≤
UP03]
(Hz)
45
5.24
Programming
To enter programming:-
1) Select (menu). Use the buttons
(plus) or
(minus) to select the
parameter to be modified and confirm with
(enter).
2) Use the buttons
(plus) or
(minus) to select the parameter to be
modified and confirm with
(enter).
3) Using buttons
(plus) or
(minus) increase or decrease the value. From
this moment the set-up icon
start blinking until the value is confirmed
with (enter).
4) To exit the program, push
(menu) until when you arrive back on the initial
display screen. The set-up icon
will disappear once the action is
complete.