SECTION 8 - MAGNETIC FLOAT REPLACEMENT
The parts required to replace the magnetic float are:
ITEM
QTY
15 Magnetic Float
2
16 Clip
2
•
DISASSEMBLY
•
Isolate electrical supply before fitting replacement part.
•
Carefully remove pipe retainer clip, washer and ‘O’-ring (Fig. 38).
•
Remove clip (item 16) using needle nose pliers (Fig. 38).
•
Remove magnetic float (item 15) using needle nose pliers (Fig. 38).
Damaged components must be replaced. Contact Stuart Turner for advice
on replacements not supplied with kit.
•
REASSEMBLY
Reassembly is the reverse of the disassembly instructions with the new replacement parts
fitted as required.
•
INITIAL OPERATING INSTRUCTIONS
•
Consult instruction manual for commissioning instructions.
•
Do not run pump dry. Allow the water to be pumped to enter the pump body thus ensuring
the seal is lubricated before switching the pump on. Failure to do this will damage the
seal.
•
Carefully check pump and pipework for leaks whilst pump running and stationary before
leaving the installation unattended.
Fig. 38
16
15
Flow Switch Body
Pipe Retainer Parts