offff
AC
100 to 240 VAC
50/60 Hz
1.20 A
0.05 A
N/A
DC
12.5 to 16 VDC
N/A
4.16 A
0.20 A
10 VDC
IIn
nsstta
alllliin
ng
g tth
he
e S
SM
MR
RT
T cch
ha
arrg
ge
err
When installing the S
SM
MR
RT
T charger, place the S
SM
MR
RT
T charger in an environmentally controlled location that is:
•
Free of excessive dust and moisture
•
Kept within a constant temperature range. An allowable temperature range is 43 °F to 88 °F (6 °C to 31 °C). The optimal
temperature range is 65 °F to 75 °F (18 °C to 24 °C).
•
Readily accessed for use
Locate and maintain the power supply and power cords to minimize the risk of damage and inadvertent disconnections.
IIn
nsstta
alllliin
ng
g tth
he
e o
op
pttiio
on
na
all m
mo
ou
un
nttiin
ng
g b
brra
acckke
ett
W
WA
AR
RN
NIIN
NG
G
•
Always have a certified mechanic, familiar with ambulance vehicle construction, install the optional mounting bracket
and the S
SM
MR
RT
T charger.
•
Always mount the S
SM
MR
RT
T charger to the optional mounting bracket in an enclosed cabinet and out of patient reach
during transport to comply with established crash test standards.
•
Always make sure that the optional mounting bracket is securely attached to the surface.
To install the optional mounting bracket (Figure 28):
1. Use the S
SM
MR
RT
T charger mounting bracket as a template to mark the location of the mounting holes (A) at the area where
you will install the mounting bracket.
2. Position the mounting bracket, making sure that the:
a. Spring tab (B) is located at the rear of the S
SM
MR
RT
T charger.
N
No
otte
e -- When mounting the bracket to a vertical surface, the spring tab should be horizontal with the spring tab point
to the left (Figure 28).
b. Power cord easily plugs into the rear of the S
SM
MR
RT
T charger.
c. S
SM
MR
RT
T charger slides from front to back to connect to the bracket after mounting.
d. Bracket is installed correctly for the ambulance or station location:
A
Am
mb
bu
ulla
an
ncce
e llo
occa
attiio
on
n
S
Stta
attiio
on
n llo
occa
attiio
on
n
•
Secure the bracket to a horizontal structural support
surface or shelf using size #10, grade 5 screws
minimum (not supplied).
•
Make sure that the selected mounting surface is strong
enough to securely hold the S
SM
MR
RT
T charger and S
SM
MR
RT
T
Pak during transport.
•
Locate the bracket in an enclosed cabinet and out of
patient reach during transport.
•
Allow for easy S
SM
MR
RT
T Pak installation and removal.
•
Locate the power supply within reach of the power cord.
•
Secure the bracket to a horizontal or vertical structural
support surface using size #10, grade 5 screws
minimum (not supplied).
•
For vertical installation, position the mounting bracket
so the spring tab is directly below the mounting screws,
so the S
SM
MR
RT
T Pak remains supported by the S
SM
MR
RT
T
charger even if the release button is accidently pressed.
•
Allow for easy S
SM
MR
RT
T Pak installation and removal.
•
Locate the power supply within reach of the power cord.
6516-209-001 Rev D.0
43
EN
Summary of Contents for 6516
Page 2: ......
Page 62: ...6 65 50 06 60 00 00 01 10 00 01 16 6 Rev AA A A 650600010130 2 EN 58 6516 209 001 Rev D 0 ...
Page 63: ...6 65 50 00 0 0 00 02 2 0 02 28 8 Rev A A A 6500 001 160 1 6516 209 001 Rev D 0 59 EN ...
Page 64: ...6 65 50 00 0 1 10 02 2 0 01 15 5 Rev AA A A 6500 102 014 1 EN 60 6516 209 001 Rev D 0 ...
Page 66: ...6 65 50 00 0 0 00 02 2 1 15 59 9 Rev AA A A 6500 002 159 1 EN 62 6516 209 001 Rev D 0 ...
Page 67: ...6 65 50 00 0 2 20 01 1 1 14 48 8 Rev AA A A 6500 201 248 1 6516 209 001 Rev D 0 63 EN ...
Page 68: ...6 65 50 00 0 2 20 01 1 0 01 10 0 Rev AA A A 6500 201 140 1 EN 64 6516 209 001 Rev D 0 ...