![Stryker 6516 Operation Manual Download Page 13](http://html.mh-extra.com/html/stryker/6516/6516_operation-manual_1385843013.webp)
3
Cot is weighed with one battery and without incubator.
4
Set the cot height to any ambulance deck height that ranges from 26 in. to 36 in. (66 cm to 91 cm).
Stryker reserves the right to change specifications without notice.
P
Po
ow
we
err--P
PR
RO
O IT is designed to conform to the Federal Specification for the Star-of-Life Ambulance (KKK-A-1822).
P
Po
ow
we
err--P
PR
RO
O IT is designed to be compatible with some competitive cot fastener systems.
The yellow and black color scheme is a proprietary trademark of Stryker Corporation.
Stryker hereby declares that this P
Po
ow
we
err--P
PR
RO
O is in compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC. Contact Stryker Medical at 3800 E. Centre Ave. Portage, MI 49002 Attn. Regulatory
Affairs to obtain a copy of the original declaration of conformity.
E
En
nvviirro
on
nm
me
en
ntta
all cco
on
nd
diittiio
on
nss
O
Op
pe
erra
attiio
on
n
Temperature
130 °F
(54 °C)
-30 °F
(-34 °C)
Relative humidity
93%
0%
Atmospheric pressure
1060
hPa
700
C
CA
AU
UT
TIIO
ON
N -- This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their expense.
S
Sp
pe
ecciiffiicca
attiio
on
nss -- S
SM
MR
RT
T
S
SM
MR
RT
T cch
ha
arrg
ge
err
S
SM
MR
RT
T P
Pa
akk
A
AC
C p
po
ow
we
err ssu
up
pp
pllyy
Electrical input
13.9 VDC 4.16 A
Not applicable
100-240 VAC
1-2 A 50/60 Hz
Electrical output
Open circuit 40 VDC 1.20 A
24 VDC NiCd
12 VDC 4-6 A
Height
2.375 in. (60.325 mm)
3.25 in. (82.55 mm)
Varies
Width
5.125 in. (130.175 mm)
4 in. (101.6 mm)
Varies
Length
7 in. (177.8 mm)
5.75 in. (146.05 mm)
Varies
Weight
1.3 lb (.59 kg)
3.8 lb (1.7 kg)
Varies
Enclosure protection
IPX0
IPX6
IPX0
Equipment type
Not applicable
Not applicable
Class II
Approvals
ANSI/AAMI ES 60601-1:
2012, CAN/CSA-C22.2 No.
60601-1:14
Not applicable
Not applicable
6516-209-001 Rev D.0
9
EN
Summary of Contents for 6516
Page 2: ......
Page 62: ...6 65 50 06 60 00 00 01 10 00 01 16 6 Rev AA A A 650600010130 2 EN 58 6516 209 001 Rev D 0 ...
Page 63: ...6 65 50 00 0 0 00 02 2 0 02 28 8 Rev A A A 6500 001 160 1 6516 209 001 Rev D 0 59 EN ...
Page 64: ...6 65 50 00 0 1 10 02 2 0 01 15 5 Rev AA A A 6500 102 014 1 EN 60 6516 209 001 Rev D 0 ...
Page 66: ...6 65 50 00 0 0 00 02 2 1 15 59 9 Rev AA A A 6500 002 159 1 EN 62 6516 209 001 Rev D 0 ...
Page 67: ...6 65 50 00 0 2 20 01 1 1 14 48 8 Rev AA A A 6500 201 248 1 6516 209 001 Rev D 0 63 EN ...
Page 68: ...6 65 50 00 0 2 20 01 1 0 01 10 0 Rev AA A A 6500 201 140 1 EN 64 6516 209 001 Rev D 0 ...