Electric Boilers
SET DHW FLOW & TEMPERATURE
The hot water side of the electrical combination boiler relies on setting the correct flow rate of water going in to
the unit, if the water going in to the unit is too fast then the unit will be unable to cope with the demand and the
water will come out cold. You should aim to set your boiler to approximately the following flowrates, you can do
this by restricting the isolation valve fitting on the cold water of the inlet during installation.
Rated Boiler Output
7kW
11kW
14.4kW
18kW
21kW
24kW
Recommended Flowrate (LPM)
4
6
8
10
12
13
With the hot water tap open and running the temperature of the hot water outlet can now be set on the boiler by
using the up and down button. The temperature cannot be adjusted without a hot tap being open. Remember
this setting does not guarantee the output, it only sets the maximum possible output, the output temperature will
rely on the flow rate going in to the boiler as above.
COMBINATION BOILERS ONLY