11
BA_VTD410EV-SEPC1_A1_140417_en
Positions:
The machine requires two needle positions and, depending on sewing drive,
possibly also a reference position.
Reference position (if necessary, e.g. sewing drive DC1500-AB322A (Fig. 4)):
The reference position needs to be set so that the tip of the needle
concludes with the outer transport table edge in the direction of the
piercing.
Fig. 4
Needle position (when stop outside the stitch (
This needle position is important for inserting and removing the material
and is achieved by stepping back the right pedal (pedal position -2).
The needle position needs to be set so that the tip of the needle
concludes at a distance of 7 mm from the outer transport table edge in the
direction of the piercing. The tip is located thereby over the table.
The needle position is position 2 at the sewing drive.
Fig. 5