12
ATI SP 80, 120, 220, 300, 400 – INSTALLATION INSTRUCTIONS
Sept - 01
POS.
DESCRIPTION
POS.
DESCRIPTION
1
motor cover
48
pipe support
2
bracket for pressure switch
49
burner bar
3
differential pressure switch
50
olive diam.10
4
silicon 5 x 8 tube for pressure switch
51
screen fitting (France and Belgium only)
5
30 W fan motor
52
fitting with pressure tale-off
6
9 x 110 fan support flange
53
control box fixing bracket for mod. 80/120
7
motor insulation 9 x 110 x 2
54
lock-out light and reset button
8
curve probe for pressure switch
55
green burner (on) light
10
fan 75 x 45
56
thermometer
11
flue hood casing 220 x 100
57
instrument support panel
12
insulating spacer 140 x 140 x 4
58
knob for control thermostat
13
fan casing
59
ON / OFF switch
14
flue outlet venture connection
60
sight glass
19
silicon gasket 84 x 22,5
61
adjustable control thermostat TR2
20
motor fixing seal 10 x 5,3
62
sight glass frame
21
upper casing cover
63
spring for casing stud
22
flue baffle
64
lower casing cover
23
hot water outlet pipe for mod. 80
65
stud for fitting casing
23b
hot water outlet pipe for mod. 120
67
hammer finish aluminium
24
brass elbow 1/2 x 14
68
lower corner pieces for casing
25
connection 1-1/4 x 1/2 DX D.53
70
cable gland support
27
magnesium anode for mod. 80 / 120
71
cable gland
28
insulated tank mod. 80
72
casing mod. 80
28b
insulated tank mod. 120
72b
casing mod. 120
30
casing front for mod. 80
73
self-adhesive NYLON
30b
casing front for mod. 120
74
combustion chamber case
31
safety limit thermostat
77
fixing pins
32
pocket for probe
78
silicon profile 16 x 8,5 x 0,7
33
seal for cover
79
sight glass gasket
34
cold water inlet pipe
190
stainless steel burner screen
35
N/A UK
191
insulation for burner screen 150 x 150 x 3
36
Honeywell control box
193
solenoid for gas valve WR 25M42S
37
wiring for mod. 80/120
195
air diverter for mod. 80
38
gas inlet pipe for mod. 80/120
195a
air diverter for mod. 120
39
gas valve WR 25M42S
196
lower corner piece for casing
40
gas pipe to the burner
197
terminal block
41
gas pressure point
198
clean out and inspection flange diam. 85
42
compression nut D=10 - 3/8"
199
3 way Molex plug for Honeywell control box
43
injector support connection CH 17 x 23,5 x 3/8G
200
5 way Molex plug for Honeywell control box
44
natural gas injector S16_200 hole D 2,00
201
wall hung brackets
44a
LPG gas injector S16_115 hole D 1,15
202
NYLON cable clamp
45
detection electrode
203
electronic package for gas valve
46
ignition electrode
204
rubber grommet
47
pipe securing bracket