M-X5-GUI-8CH-2013_Q3
More information
www.streamaxtech.com
Copyright
2012-2014, Streamax Technology Co., Ltd
All Rights Reserved
All specifications are therefore subject to change without notice.
VIDEO TYPE:
PAL and NTSC optional. The default setting is NTSC
RECORD MODE:
Record mode, three modes as following:
GENERAL:
When MDVR is power supplied and starts up, the MDVR will start to record automatically.
TIMER:
This is the switch to start the TIMER recording function. Only you enable this switch, MDVR will
start to record at configured certain time setting in the TIMER RECORD menu based on the
SCHEDULE menu
EVENT:
This is the switch to start the event recording. Only you enable this switch, when event is trigged,
MDVR will create event record.
NORMAL REC RATE:
normal record rate, two option:
NORMAL:
MDVR will start to record according to the setup of RECORD SETTING.
I FRAME:
MDVR only record by I frame (the key frame for video) in order to take less space of hard drive.
BUT when event is trigged, MDVR will record according to setup of RECORD menu.
RECORD FILE TIME
(
MIN
)
:
Recording file packing size, 15, 30, 45, 60 minutes optional.
ALARM DURATION
(
3-30
)
SEC:
The alarm duration time, all the alarm for same type considered to be one alarm
during the time which is configured for alarm duration. For example, if the
setting for alarm duration is 10 sec and during this 10 sec, anther same type
(like panic button) alarm triggered, MDVR system will consider them to be one
alarm event. And the alarm start time will be reset based on the second time for
alarm.
ALARM POST REC
(
30-1800
)
SEC:
Alarm post recording time.
BUZZER TIME:
buzzer alarm duration time setup when alarm is triggered