FOOTINGS HAVE BEEN BASED ON THE FOLLOWING SOIL PROPERTIES:

SOIL TYPE

COHESION (psi)

FRICTION ANGLE

SANDY

0.7

35°

SANDY CLAY

3.5

25°

CLAY

5

15°

NOTE: It is assumed that the soil is natural and in a relatively undisturbed 

state

PANEL ONLY

For Ezi-Slat being used in ‘Panel Only’ applications, i.e. 
secured between timber, steel or brickwork structural 
supports designed by others the following panel spans are 
applicable:

FOOTINGS

Footings shall be founded in natural soil only. Concrete shall 
have a minimum strength of 3000 PSI. The top of footings 
shall be shaped to direct water away from the base of posts 
and steel contact with moisture retaining material such as 
soil, paving sand and garden debris is to be avoided.

POST SIZE

(GRADE C350)

MINIMUM FOOTING SIZE:

Ø X DEPTH (INCHES)

SANDY

SANDY 

CLAY

CLAY

2.55 x 2.55 x 0.1in SHS 

(65x65x2.5mm)

12 X 45

10 X 35

10 X 30

MAXIMUM ALLOWABLE PANEL SPAN, feet (mm)

BASIC WIND 

(mph)

PANEL TYPE

EXPOSURE

B

C

110

General Panels

7.9 (2400)

7.9 (2400)

Return Corner Panels

7.9 (2400)

7.9 (2400)

Free End Panels

7.9 (2400)

6.9 (2100)

150

General Panels

7.9 (2400)

6.9 (2100)

Return Corner Panels

6.9 (2100)

5.9 (1800)

Free End Panels

6.9 (2100)

5.9 (1800)

h

B

Aspect Ratio = 

B

/

h

Free End

Return Corner

General Panels

0-1h

1h-2h

Free End Panels

Return Corner

Panels

0-1h

Ezi-Slat Fence

ENGINEERED EZI-SLAT FENCE

Summary of Contents for Fence Sanctuary Ezi-Slat Fencing

Page 1: ...Fence Solution Design fence loading determined in accordance with ASCE SEI 7 10 Minimum Design Loads for Buildings and other structures Non Engineered Panels Suitability of the slat supporting struct...

Page 2: ...lat Plain Receiving Rail Optional components 12g x 3 75mm Pan Head Screw 10g x 3 4 20mm Wafer Head Self Drilling Screw 12g x 11 2 39mm Hex Head Self Drilling Screw 10g x 5 8 16mm Hex Head Self Drillin...

Page 3: ...PANEL COMPONENT DIAGRAM 4 5 3 2 1 1 2 3 1 8g x 11 5 30mm COUNTERSUNK SCREWS 2 RECEIVING RAIL CAPS 3 RECEIVING RAIL 4 SPACER 5 SLAT...

Page 4: ...fencing which is located closer than 3000 feet from these environments increased inspection and maintenance is required refer to the Stratco Product Maintenance Severe Environment Considerations broch...

Page 5: ...ped to direct water away from the base of posts and steel contact with moisture retaining material such as soil paving sand and garden debris is to be avoided POST SIZE GRADE C350 MINIMUM FOOTING SIZE...

Page 6: ...es between posts are correct STEEL SPIGOT INTO CONCRETE A 11 2 x11 2 x1 6 40x40x4 0mm SHS steel spigot can be installed into concrete Figure 1 2 The spigot must protrude from the concrete a minimum of...

Page 7: ...ing two 8g x 11 5 30mm countersunk screws Figure 2 1 The cap may need to be knocked in using a rubber mallet Use a low torque setting on the drill to avoid snapping the screws Post Base Plate 4x 12g x...

Page 8: ...into the receiving rail Figure 2 4 Continue to insert slats followed by spacers until the slats reach the top of the receiving rail Figure 2 5 POST CAPPING Gently tap in the Post Cap and Rail Cap usi...

Page 9: ...ons of the gate hinges as per the hinge manufacturer s instructions Rail Packers are used to provide a square mounting point on the Gate Receiving Rail Position the hinges on the Rail Packer and mark...

Page 10: ...ts that may reduce the life of the product Stratco steel and aluminum products that are regularly washed by rain require minimal maintenance No Stratco steel or aluminum structure or materials are rec...

Reviews: