background image

PANEL ASSEMBLY

PRE-DRILL RECEIVING RAIL

Measure and mark the holes for mounting the Receiving 
Rail to the posts. The top and bottom holes are to be a 
maximum of 4/5” (20mm) from the end of the rail. The 
remaining holes are to be spaced evenly at a maximum of 

18” (450mm) centres (Figure 2.0). 

Pre-drill the Receiving Rail mounting holes using a 3mm or 

1/8” drill bit.

INSTALL BOTTOM RECEIVING RAIL CAP

Push receiving rail cap into the receiving rail and fasten using 
two 8g x 11/5” (30mm) countersunk screws (Figure 2.1). The 
cap may need to be knocked in using a rubber mallet. Use a 
low torque setting on the drill to avoid snapping the screws.

Post

Base Plate

4x 12g x 3” Pan Head Screws

FIGURE 1.4

Four M10
Masonry
Anchors

Four

ø

25

64

(

ø

10mm)

Holes

3”

(75mm)

3” (75mm)

(Min.)

3”

(75mm)

3” (75mm)

(Min.)

FIGURE 1.5

Screw Locator Groove

*Maximum 18” (450mm) centres

4

5

(20mm)

*Hole centre distance varies depending 
on height of fence panel. Maximum 
distance between holes to be 18” 
(450mm). Installer to determine 
spacing and number of screws 
required.

4

5

(20mm)

FIGURE 2.0

Receiving Rail Cap

Receiving Rail

2x 8g x 1

1

5

” (30mm)

Countersunk Screws

FIGURE 2.1

Summary of Contents for Fence Sanctuary Ezi-Slat Fencing

Page 1: ...Fence Solution Design fence loading determined in accordance with ASCE SEI 7 10 Minimum Design Loads for Buildings and other structures Non Engineered Panels Suitability of the slat supporting struct...

Page 2: ...lat Plain Receiving Rail Optional components 12g x 3 75mm Pan Head Screw 10g x 3 4 20mm Wafer Head Self Drilling Screw 12g x 11 2 39mm Hex Head Self Drilling Screw 10g x 5 8 16mm Hex Head Self Drillin...

Page 3: ...PANEL COMPONENT DIAGRAM 4 5 3 2 1 1 2 3 1 8g x 11 5 30mm COUNTERSUNK SCREWS 2 RECEIVING RAIL CAPS 3 RECEIVING RAIL 4 SPACER 5 SLAT...

Page 4: ...fencing which is located closer than 3000 feet from these environments increased inspection and maintenance is required refer to the Stratco Product Maintenance Severe Environment Considerations broch...

Page 5: ...ped to direct water away from the base of posts and steel contact with moisture retaining material such as soil paving sand and garden debris is to be avoided POST SIZE GRADE C350 MINIMUM FOOTING SIZE...

Page 6: ...es between posts are correct STEEL SPIGOT INTO CONCRETE A 11 2 x11 2 x1 6 40x40x4 0mm SHS steel spigot can be installed into concrete Figure 1 2 The spigot must protrude from the concrete a minimum of...

Page 7: ...ing two 8g x 11 5 30mm countersunk screws Figure 2 1 The cap may need to be knocked in using a rubber mallet Use a low torque setting on the drill to avoid snapping the screws Post Base Plate 4x 12g x...

Page 8: ...into the receiving rail Figure 2 4 Continue to insert slats followed by spacers until the slats reach the top of the receiving rail Figure 2 5 POST CAPPING Gently tap in the Post Cap and Rail Cap usi...

Page 9: ...ons of the gate hinges as per the hinge manufacturer s instructions Rail Packers are used to provide a square mounting point on the Gate Receiving Rail Position the hinges on the Rail Packer and mark...

Page 10: ...ts that may reduce the life of the product Stratco steel and aluminum products that are regularly washed by rain require minimal maintenance No Stratco steel or aluminum structure or materials are rec...

Reviews: