FP10 Lafayette - Installation and Operation Manual
63
8.7
Angled Wall Radiation Shield
When passing through a combustible wall with the chimney at a 30
or 45
angle (30
or 45
in Canada and
30
only in the USA), an angled firestop or wall radiation shield provided by the chimney manufacturer must
be installed. Only one is required. Fo
llow the chimney manufacturer’s installation instructions.
In cold climate locations, it is recommended that you use the insulated wall radiation shield since it will
maintain the home’s thermal barrier.
A
INSULATED WALL RADIATION SHIELD
B
GYPROCK
C
INSULATED WALL
8.8
Chimney Support Installation
8.8.1
Universal Roof Support
This support has three possible uses:
1.
It must be used on a roof to support the chimney.
2.
It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
3.
It may be used on a floor, ceiling or roof as a supplementary support.
For roof support installation, refer to the instructions provided with the support by the chimney
manufacturer. Many manufacturers will provide the maximum height of chimney that can be supported by
the support. Make sure you respect those parameters.