background image

27 

26 

Do not immerse any plastic 
components in alcohol or eth-
anol for longer than an hour. 

Extended contact with alcohol or eth-
anol can lead to discoloration or em-
brittlement of plastic parts. 
Before assembling allow all compo-
nent parts to dry properly. 
After cleaning, check all component 
parts for surface damage, tears, sof-
tening or hardening, impurities, dis-
tortion and discoloration and set dam-
aged component parts aside. 

Warning! Alcohol (ethanol) 
is flammable and may easi-
ly ignite.

Sets of new Cooling Units 
may be ordered from 

www.

storz-bickel.com

10.3.  Removal of the Lower Filling 

Chamber Screen

Remove the lower Filling Chamber 
Screen out of the Filling Chamber by 
using a pair of tweezers or a pair of 
pointed pliers. Insert a new Screen 
while taking care that the edges of the 
Screen seat into the groove at the bot-
tom of the Filling Chamber.

10.2.  Cleaning  the 

MIGHTY

 Cooling 

Unit

The Cooling Unit can be disassem-
bled for cleaning purposes and then 
assembled again (see Chapter 10.1. 
“Disassembling and Reassembling 
the 

MIGHTY

 Cooling Unit”, page 

24). 
The Cleaning Brush, cotton swabs 
and paper or cotton towels may be 
used for cleaning. As solvent, we rec-
ommend alcohol (ethanol) or warm 
water with wash-up liquid. 
For optimal airflow, please ensure 
the Cooling Unit and Mouthpiece are 
clean and free from debris blockage.

Manual cleaning of the disassembled 
Cooling Unit

10. DISASSEMBLING, CLEANING AND ASSEMBLING

11. ACCESSORIES 

11.1. Dosing Capsules and Magazin

Dosing Capsules with Magazine

With the Dosing Capsules, which are 
available as accessories, you can fill 
ground plant material or aromatic oils 
using the Liquid Pads into the Dosing 
Capsules in advance and store them 
in the Magazine. This facilitates the 
handling. 

Filling the Dosing Capsules with 
ground Plant Material

The plant material has to be ground 
with the included Herb Mill first.
The Dosing Capsules can be filled 
with ground plant material per Cap-
sule and be stored in the Magazine as 
a reserve.  

Dosing Capsule with removed cap 

Grind the plant material and fill the 
Dosing Capsule by using the Maga-
zine Cap (funnel). 

Dosing Capsule while being filled with 
Magazin Cap (funnel)

Attach the cap onto the Dosing Cap-
sule. Repeat the filling process until 
the desired amount of Dosing Cap-
sules is filled and insert them into the 
Magazine. The Magazine can hold up 
to 8 Dosing Capsules.

Summary of Contents for Mighty

Page 1: ...STORZ BICKEL GMBH CO KG INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions ...

Page 2: ... Filling Chamber 19 8 1 Filling Aid 20 8 2 Filling the Filling Chamber Using the Filling Aid 21 9 Application 22 10 Disassembling Cleaning and Assembling 23 10 1 Disassembling and Reassembling the MIGHTY Cooling Unit 24 10 2 Cleaning the MIGHTY Cooling Unit 26 10 3 Removal of the Lower Filling Chamber Screen 26 INSTRUCTIONS FOR USE ENGLISH Table of Contents page 11 Accessories 27 11 1 Dosing Capsu...

Page 3: ...device repairs warranty claims and disposal of the device customers in the US and Canada should contact the following address Storz Bickel America Inc 1078 60th Street Suite A Oakland CA 94608 All other customers should contact this address Storz Bickel GmbH Co KG In Grubenäcker 5 9 78532 Tuttlingen Germany 1 PRODUCT OVERVIEW MIGHTY VAPORIZER ON OFF Switch Type Label on the rear Minus Temperature ...

Page 4: ...ance of the product with the applicable European directives and standards The device was introduced after 13 August 2005 It may not be disposed of in normal household waste The X on the trash can indicates the necessity of disposing of this device separately The device contains a built in rechargeable lithium ion battery that must be discharged before disposal Symbol for the manufacturer the manuf...

Page 5: ...n a dry place protected against the effects of weather and out of the reach of children or unqualified persons It cannot be used in damp locations such as bathrooms etc 2 SAFETY RECOMMENDATIONS Do not operate the Vaporizer close to flammable objects such as curtains tablecloths or paper Keep the Vaporizer and power adapter away from pets e g hamsters mice and other animals which could damage the i...

Page 6: ...inalis the leaves 190 C 374 F Thyme Thymus vulgaris the herb 190 C 374 F Below is an overview of the plants that are suitable for vaporization in the MIGHTY Vaporizer The aromas and fragrances from the plant materials listed below may be vaporized Any other use is inappropriate and po tentially dangerous It is important to observe the following instructions in order to set the MIGHTY Vaporizer wit...

Page 7: ...ial source of dan ger Please dispose of the packing mate rial in a proper and environmentally friendly manner We recommend keeping the original packaging in case it is required later transport Storz Bickel Service Center etc 6 THE MIGHTY VAPORIZER Power Connection Before connecting up the Vaporizer make sure that the information given on the power adapter type label cor responds to the local power...

Page 8: ...er on soft surfaces or flammable material Check whether the power adapter supply voltage cor responds to the voltage rating listed on the power adapter The power adapter cord and power adapter must be in perfect condition Connect the power adapter only to a properly in stalled socket The manufacturer will not bear any responsibility whatsoever if this acci dent prevention measure is not taken Plea...

Page 9: ... two temperature levels that are set in the factory The basic temperature at 180 C 356 F and the booster tem perature at 195 C 383 F Switch on the device heating up the Vaporizer with full Filling Chamber and Cooling Unit mounted is recom mended To do this press the orange ON OFF switch for at least half a sec ond The Vaporizer responds with a 7 COMMISSIONING AND OPERATION short vibration The vibr...

Page 10: ...LING CHAMBER Turn the Cooling Unit with a 90 rota tion counterclockwise in order to re move it from the Vaporizer Always fill the Filling Chamber com pletely up to the plastic rim with ground plant material Do not com Removal of Cooling Unit with Mouthpiece Filling Chamber properly filled Filling Chamber partially filled with Liquid Pad placed on top press the plant material too much so that the a...

Page 11: ...azine for transporting and storing plant material already ground in the Herb Mill To fill the Filling Aid remove the up per cap and fill the bowl incl plug with ground plant material Replace the upper cap and close it 8 2 Filling the Filling Chamber Us ing the Filling Aid Remove the Cooling Unit from the Va porizer and remove any residues that may be in the Filling Chamber The Filling Chamber Tool...

Page 12: ...or lung conditions Depend ing on the density the vapor could ir ritate respiratory tracts or lungs which can lead to coughing Inhale only half of air you can normally manage Hold your breath for a few seconds and exhale slowly It is advisable to delib erately concentrate on your breathing process After vaporization turn off the MIGHTY Vaporizer To do this press the orange ON OFF switch for at leas...

Page 13: ...bel or disintegration of the glue Removal of the Cap Lock Separate the Cooling Unit Cap from the Cooling Unit Base by pulling off the cap upwards Removal of the large Base Seal Ring Remove the large and small Base Seal Rings Lever out the large Seal Ring from the recess in the notch us ing the Filling Chamber Tool Reassemble in reverse order When assembling make sure that Seal Rings are properly s...

Page 14: ...ush cotton swabs and paper or cotton towels may be used for cleaning As solvent we rec ommend alcohol ethanol or warm water with wash up liquid For optimal airflow please ensure the Cooling Unit and Mouthpiece are clean and free from debris blockage Manual cleaning of the disassembled Cooling Unit 10 DISASSEMBLING CLEANING AND ASSEMBLING 11 ACCESSORIES 11 1 Dosing Capsules and Magazin Dosing Capsu...

Page 15: ...y turning it clockwise Inserting the Dosing Capsules Turn the Cooling Unit with a 90 rota tion counterclockwise in order to re move it from the MIGHTY Vaporizer Removal of Cooling Unit with Mouthpiece 11 ACCESSORIES The inserted Dosing Capsule Insert the Dosing Capsule into the Filling Chamber of the MIGHTY Va porizer Then re mount the Cooling Unit by ro tating it clockwise through 90 The Filling ...

Page 16: ...Every further use beyond this or the use of damaged and or contaminated products respectively is the user s re sponsibility We assume no liability if this recom mendation is ignored Please note that damaged or brittle Lip Pieces are not to be used Power Adapter Power consumption 36 W Supply voltage 100 240 V 50 60 Hz Output voltage 12 V DC MIGHTY Vaporizer Supply voltage 12 V DC The voltage detail...

Page 17: ... tear Upon delivery Customer shall imme diately inspect the Products for con formity and visible defects Customer shall give Company immediate written notice of any non conformities or vis ible defects regarding the Products and contact Company in writing con cerning return or repair as the case may be Warranty Customer shall notify Company in writing of any defects of the Products Company s sole ...

Page 18: ...such damages Company s liability for damages aris ing out of or in connection with this agreement shall in no event exceed the purchase price of the Products It is agreed and acknowledged that the provisions of this agreement allocate Repair Service After the warranty period has expired or if there are any defects which are not covered under warranty our ser vice department will repair the defect ...

Page 19: ... GMBH CO KG In Grubenäcker 5 9 78532 Tuttlingen Germany STORZ BICKEL AMERICA INC 1078 60th St Suite A Oakland CA 94608 by STORZ BICKEL GmbH Co KG MAL 30 204 03 2017 sec_EN Subject to alterations All rights reserved ...

Reviews: