APPENDIX Ⅰ LIGHTNING PROOF AND SURGE
PROTECTION
This series speed dome adopts TVS lighting protection technology. It can effectively prevent
damages from various pulse signals below 1500W, such as sudden lighting and surge. While
maintaining your local electrical safety code, you still need to take necessary precaution
measures when installing the speed dome in the outdoor environment.
The distance between the signal transmission cable and high-voltage device (or high-voltage
cable) shall be at least 50 meters.
Outdoor cable layout shall go under the penthouse if possible.
For vast land, please use sealing steel tube under the land to implement cable layout and
connects one point to the earth. Open floor cable layout is forbidden.
In area of strong thunderstorm hit or near high sensitive voltage (such as near high-voltage
transformer substation), you need to install additional high-power thunder protection device or
lightning rod.
The thunder protection and earth of the outdoor device and cable shall be considered in the
building whole thunder protection and conform to your local national or industry standard.
System shall adopt equal-potential wiring. The earth device shall meet anti-jamming and at
the same time conforms to your local electrical safety code. The earth device shall not short
circuit to N (neutral) line of high voltage power grid or mixed with other wires. When connect
the system to the earth alone, the earth resistance shall not be more than
4Ω and earth cable
cross-sectional area shall below 25 mm2. See Figure 7-1.
Figure 7-1
Summary of Contents for VUDO2PTZIR30X
Page 1: ...VUDO2PTZIR30X 2 1MP Full HD 30X PTZ IP Dome Camera with IR Installation Manual Version 1 0 1 ...
Page 17: ...9 Figure 1 12 ...
Page 20: ...12 Figure 2 3 2 4 Pole Mount Bracket The pole mount bracket is shown as below See Figure 2 4 ...
Page 21: ...13 Figure 2 4 ...
Page 24: ...16 Figure 3 3 ...
Page 30: ...22 Figure 5 3 ...
Page 33: ...25 Figure 6 3 ...
Page 38: ...30 mm Feet m w 0 8000 1 000 1 250 2 000 100 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 ...
Page 40: ...32 mm Feet m w 0 8000 1 000 1 250 2 000 100 6 11 1 86 9 54 2 91 14 91 4 54 38 17 11 63 ...