29
Gültig seit/Valid from/Valide: 09.10.2019
5.4
End the heating process
1.
At the end of the burning process (residual glow), a signal sounds and the LED display
flashes. If no fuel is loaded within 5 minutes, the control system checks the
combustion chamber:
-
If there is some fuel inside then restart is done automatically (new
burning process runs).
-
If there is no fuel inside the regulator will be switched to stand-by
mode.
2.
Thereafter, the air flap closes to 0% until the next heating process
. The automatic
burn-off control switches to standby mode (gray color on stork APP) and the LED
indicator turns off.
If you open the door without firing the regulation unit will open normally, but
after 10 minutes will fully close again to stand-by position.
During a power outage, or if automatic regulation on the central unit is turned off,
or the system is disconnected from the power network, always immediately attach
the magnetic key (5) to the servomotor (4) in order to enable manual combustion
regulation using the air intake control lever
.
Outside the heating season, we recommend disconnecting the regulator from the
power network.