19
866-795-1586 • WWW.STONEAGETOOLS.COM
AIR MOTOR GENERATOR REPLACEMENT INSTRUCTIONS
These replacement instructions describe how to replace an air motor generator within an AST-200-V2 AutoStroke.
AIR MOTOR GENERATOR REMOVAL INSTRUCTIONS
AIR MOTOR GENERATOR REPLACEMENT
NOTICE
Airline connections should be removed at least 10 minutes before servicing to allow time for stored electrical energy to dissipate.
1. Using a flat screwdriver, turn the quarter turn latches
counterclockwise 90 degrees and open the AutoStroke
enclosure.
2. Disconnect the 2 air tubes from the air motor generator
AST-200-V2 AUTOSTROKE shown without cover
Air Motor Generator location
3. Depress the tab on the back of the electrical
connector and carefully separate the electrical
connection.