14
866-795-1586 • WWW.STONEAGETOOLS.COM
HOSE CONNECTIONS
1. Connect the
BLACK
and
RED
1/2” lines from the AutoStroke “Forward” and “Reverse” connections to the “Forward” and “Reverse”
connections on the back of the CB-ABX. Connect the SHORT 1/4” I.D. Hose to the fitting marked “
CLAMP
” on the left side of the
AutoStroke to the “
CLAMP
” fitting on the Control Box.
(Figure 1)
2. Connect the LONG 1/4” I.D. Hose to the fitting marked “
CLAMP
” on the right side of the AutoStroke and the opposite end to the
“
CLAMP
” fitting on the ABX-2L or ABX-2L-V2. Insert the ends of the 1/4”
BLACK
and
RED
tubing into the press lock fittings on the
right side of the AutoStroke. Push the opposite ends of each tube into the color labeled, press lock, fittings on the manifold atop the
ABX-2L or ABX-2L-V2. Connect the
BLACK
and
RED
1/2” lines to the right side of the AutoStroke marked “Forward” and “Reverse”
and connect the opposite ends to the manifold on the ABX-2L or ABX-2L-V2.
(Figure 2 & 3)
3. Skip to the “OPERATIONS” page of this manual.
FIGURE 2
CORRECT AUTOSTROKE CONNECTION TO ABX-2L
ABX-2L AND ABX-2L-V2 AUTOSTROKE SET-UP
FIGURE 1
FORWARD
REVERSE
CLAMP TO
AUTOSTROKE
FORWARD
REVERSE
CLAMP TO
ABX-2L
FIGURE 3
NOTICE
The AutoStroke and the CB-ABX are labeled “Forward” and “Reverse”and color coded. Make sure the hoses mate to their corresponding
labeled connections on both ends.
CORRECT AUTOSTROKE CONNECTION TO CONTROL BOX