50
7
Assembly and setting up
Assembling machine
3. Open the plug (2) and connect to the mains supply (3a) or·(3b)
Mains
supply (3a)
Mains supply (3b)
Example for mains symmetry
Connection variant
Plug (2)
A
B
C
L1
L1
L1
L2
L3
L2 *
L2 **
L3 **
L1 **
L3 *
L3 **
L1 **
L2 **
N
N
N
N
N
PE
PE
PE
PE
PE
* L2 and L3 are not used internally in the machine. Therefore, the phases of the
operational mains supply must be distributed evenly on L1, L2 and L3.
** if available
4. Make sure that the operational mains supply is loaded evenly (mains
symmetry). You will find the connection variants (A, B, C) in the above
table.
5. The terminal for the protective conductor "PE" must be connected.
Potential equalization missing!
Serious faults or disturbances can be caused in the
machine and the electronic circuit if the terminal (PE)
is not connected.
-> Always connect terminal .
6. Close the plug (2) and connect it to the main switch.