SECTION 4
TROUBLESHOOTING
4.1 LIGHT INDICATORS
The machine has two lights that alert the user if a problem occurs: an ADD MIX light and a Diagnostic Light.
The ADD MIX light flashes to alert the operator to a low mix condition. It does so by monitoring the mix level in the
hopper. When the ADD MIX light is flashing, refill hopper immediately.
The Diagnostic Light is on during defrost mode and flashes if an error occurs. Refer to the chart below for details.
Indication
On
Two Blinks
Conditions
Defrost Mode
Drive current is not sensed
Self Correc-
tion
N/A
The machine attempts to sense drive current with a 3 second
pre-stir. If current is sensed, the machine returns to normal
operation. If current is not sensed, the machine waits 7 minutes
and trys to sense current with another 3 second pre-stir. After
the third attempt, the compressor runs on timers.
Operation
Every 7 minutes the auger runs
for 90 seconds.
Every 21 minutes the auger runs for 10 seconds.
Corrective
Action
N/A
Contact Service Technician