ID 442454.02
52
WE KEEP THINGS MOVING
Object directory - References
4
Operation manual CiA 402 Controller Based
4
Object directory - References
4.1
Communication objects - CiA 402
The following list of communication objects that are in the index range between
6000
hex
and 67FF
hex
, are implemented according to CiA 402
Drives and
motion control device profile
in the "CiA 402 Controller Based", "CiA 402
Controller Based HiRes Motion" and "CiA 402 Drive Based" applications.
Index
Subindex Name
STOBER
parameter
address
Comment
603F
hex
0
hex
Error code
A514
6040
hex
0
hex
Control word
A515
6041
hex
0
hex
Status word
A516
605A
hex
0
hex
Quick stop option
code
A536
605E
hex
0
hex
Fault reaction
option code
A540
6060
hex
0
hex
Modes of
operation
A541
6061
hex
0
hex
Modes of
operation display
A542
6064
hex
0
hex
Position actual
value
A545
6065
hex
0
hex
Following error
window
A546
6066
hex
0
hex
Following error
time out
A547
606C
hex
0
hex
Velocity actual
value
A553
6071
hex
0
hex
Target torque
A558
6072
hex
0
hex
Max torque
A559
6077
hex
0
hex
Torque actual
value
A564
6078
hex
0
hex
Current actual
value
A556
6079
hex
0
hex
DC link voltage
A567
6081
hex
0
hex
Profile velocity
A574
Only in CiA 402 Drive
Based
6083
hex
0
hex
Profile
acceleration
A576
Only in CiA 402 Drive
Based
6084
hex
0
hex
Profile
deceleration
A577
Only in CiA 402 Drive
Based
607A
hex
0
hex
Target position
A567
60A3
hex
0
hex
Profile jerk use
A589
Only in CiA 402 Drive
Based
60A4
hex
0
hex
Profile jerk
A590
Only in CiA 402 Drive
Based
607B
hex
0
hex
Position range
limit, Highest sub-
index supported
–
2
607B
hex
1
hex
Position range
limit, Min position
range limit
A568[0]
No function
Index
Subindex Name
STOBER
parameter
address
Comment