![Stober CiA 402 Operation Manual Download Page 23](http://html.mh-extra.com/html/stober/cia-402/cia-402_operation-manual_1381235023.webp)
ID 442454.02
23
WE KEEP THINGS MOVING
Basic information
2
Operation manual CiA 402 Controller Based
2.2.3.3.3
Referencing method 3
Referencing method 3 is characterized by the following features:
•
Positive reference switch
•
Encoder zero pulse
•
Positive initial movement
Sequence
Case I: The drive has not activated the reference switch yet.
1. The drive starts in positive direction with ramp
A588
and speed
A587.0
.
2. The drive turns around on the reference switch and changes to speed
A587.1
.
3. When the zero pulse is detected, the reference is set.
4. The drive comes to a complete stop with ramp
A588
.
Case II: The drive is already located on the reference switch.
1. The drive starts in negative direction with ramp
A588
and speed
A587.1
.
2. After the negative edge of the reference switch, the reference is set when
the zero pulse is detected.
3. The drive comes to a complete stop with ramp
A588
.
2.2.3.3.4
Referencing method 5
Referencing method 5 is characterized by the following features:
•
Negative reference switch
•
Encoder zero pulse
•
Negative initial movement
Sequence
Case I: The drive has not activated the reference switch yet.
1. The drive starts in negative direction with ramp
A588
and speed
A587.0
.
2. The drive turns around on the reference switch and changes to speed
A587.1
.
3. When the zero pulse is detected, the reference is set.
4. The drive comes to a complete stop with ramp
A588
.
Case II: The drive is already located on the reference switch.
1. The drive starts in positive direction with ramp
A588
and speed
A587.1
.
2. After the negative edge of the reference switch, the reference is set when
the zero pulse is detected.
3. The drive comes to a complete stop with ramp
A588
.
RS
3
ZP
RS
3
I
II
RS
5
5
ZP
RS
I
II