In the event of leakage, please contact the Af-
ter-Sales Service Centre.
Checking the oil level in the control-
led stabiliser circuit
–
Switch off the truck and disconnect the bat-
tery connector.
–
Remove the hood of the technical compart-
ment.
It is essential that the oil level of the stabilisers
is on the mark situated between the raised
MIN and MAX (3) lettering on the tank (2)
–
Top up the level if necessary, after un-
screwing the plug (1).
–
Screw the plug back in at the end of the op-
eration.
CAUTION
Risk of damage to the truck
Only use hydraulic oil that complies with the specifi-
cations. See table of lubricants.
–
Refit the hood of the technical compart-
ment.
–
Return the truck to service.
Maintenance
5
Hydraulic systems
119
11638011551 EN - 02/2021 - 06