Use and Operation
4
Load Placement
Forklift Use in Cold-Storage Rooms.
A truck specifically equipped for cold-storage
rooms must be used when working at temper-
atures below +5°C.
Forklifts equipped for working in cold climates
and cold-storage rooms may be used at a
minimum temperature of -5°C for continuous
service in cold-storage rooms and at -32°C
for non-continuous service in cold-storage
rooms.
CAUTION
The forklift must always be turned off and parked
outside the cold area/cold-storage room.
CAUTION
If the truck has been working in environments at
temperatures below -5°C and it is taken outside the
cold-storage room, let it stand either for a sufficien-
tly long time to allow evaporation of any condensa-
tion (at least 30 minutes) or a sufficiently short time
to prevent the formation of any condensation (less
than 10 minutes).
Avoid the formation of ice on the forklift.
CAUTION
NEVER drive the truck into the cold-storage room
when condensation has formed on it
Using the truck with extension leads
DANGER
The truck may only be used with extension leads
fitted with a filter approved by the manufacturer,
with a maximum length of 20 m.
Load Placement
Taking up load
DANGER
Before lifting the load, make sure that its dimensi-
ons and centre of gravity fall within the forklift spe-
cifications, as indicated in the TECHNICAL DATA
chapter
DANGER
The loads must be arranged so that they cannot slip
or overturn and fall to the ground.
DANGER
Make sure that nobody is standing in the forklift’s
area of operation.
45378043402 [EN]
47
Summary of Contents for ECU-SF-20
Page 1: ...Original instructions ECU SF 20 0170 45378043402 EN 10 2011 ...
Page 2: ......
Page 7: ...1 Introduction ...
Page 15: ...2 Safety ...
Page 24: ...2 Safety Safety tests 18 45378043402 EN ...
Page 25: ...3 Knowledge of the Truck ...
Page 40: ...3 Knowledge of the Truck Truck Identification 34 45378043402 EN ...
Page 41: ...4 Use and Operation ...
Page 58: ...4 Use and Operation Battery Recharging 52 45378043402 EN ...
Page 59: ...5 Maintenance ...
Page 67: ...6 Technical data ...
Page 68: ...6 Technical data Overall dimensions Overall dimensions OM1355 62 45378043402 EN ...
Page 74: ...6 Technical data 68 45378043402 EN ...
Page 76: ......
Page 77: ......
Page 78: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 45378043402 EN ...
Page 79: ...Original instructions ECU SF 20 0170 45378043402 EN 10 2011 Annex ...
Page 80: ......
Page 81: ...7 Diagrams ...
Page 85: ...Diagrams 7 Circuit diagram Diagram part 2 45378043402 EN 79 ...
Page 87: ...Diagrams 7 Circuit diagram Diagram part 3 45378043402 EN 81 ...
Page 89: ...Diagrams 7 Circuit diagram Diagram part 4 45378043402 EN 83 ...
Page 91: ...Diagrams 7 Circuit diagram Diagram part 5 45378043402 EN 85 ...
Page 92: ...STILL GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 45378043402 EN ...