![Stihl RMI 632 Instruction Manual Download Page 35](http://html.mh-extra.com/html/stihl/rmi-632/rmi-632_instruction-manual_1379499035.webp)
EN
33
0478 131 8349 A - EN
Checking the wire signal may take several
minutes. The red STOP button on top of
the machine terminates the link, the
previous installation assistant step is
called up.
Normal reception
Wire signal OK:
The text "Wire signal OK"
appears on the display. The
robotic mower and the docking
station are correctly linked.
Continue initial installation by
pressing the OK button.
Interrupted reception
The robotic mower receives
no
wire signal
:
The text "No wire signal"
appears on the display.
The robotic mower receives a
faulty wire signal
:
The text "Check wire signal"
appears on the display.
The robotic mower receives a
reversed-polarity wire signal
:
The text "Connections swapped
or iMow outside" appears on the
display.
Possible cause:
– Temporary malfunction
– Robotic mower is not docked
– Perimeter wire has been connected
incorrectly (reversed polarity)
– Docking station is switched off or not
connected to mains supply
– Faulty plug connections
– Minimum perimeter wire length not
reached
– A coiled power cable in the vicinity of
the docking station
– Perimeter wire ends excessively long or
not sufficiently twisted together
– Perimeter wire break
– Extraneous signals such as a mobile
phone or the signal from another
docking station
– Live underground cables, reinforced
concrete or disruptive metals in the
ground under the docking station
– Maximum length of the perimeter wire
Remedy:
– Repeat linking without other corrective
action
– Connect the perimeter wire ends
– Check the docking station mains
connection, roll out the power cable in
the vicinity of the docking station, do not
set down coiled
– Check the seating of the wire ends in
the terminal block, shorten excessively
long wire ends and twist the wire ends
together (
– For mowing areas < 100 m² or a wire
length < 175 m, the accessory
AKM 100
must be installed together
– Check the LED indicator on the docking
– Repair the wire break
– Switch off mobile phones or nearby
docking stations
– Change the position of the docking
station or remove interference sources
under the docking station
– Use a perimeter wire with larger cross
section (special accessory)
Following the appropriate corrective
action, repeat linkage by pressing
the OK button.
RMI 632 C, RMI 632 PC:
"Standard" energy mode is
activated following successful
linking. (