EN
27
0478 131 8349 A - EN
Provide a free wire end (1) with a length of
approx.
1.5 m
.
Route the perimeter wire (2) in front of and
behind the docking station (1) for
0.6 m
in
a straight line and at right angles to the
floor plate. Then follow the edge of the
mowing area with the perimeter wire.
Starting routing with an external
docking station:
Fasten the perimeter wire (1) to the ground
on the
left
or
right
as appropriate, behind
the floor plate, directly next to a wire outlet,
using a fixing pin (2).
Provide a free wire end (1) with a length of
approx.
2 m
.
Route the perimeter wire (2) in front of and
behind the docking station (1) with 50 cm
of clearance and at right angles to the floor
plate. A corridor can then be installed
(
12.11) or the edge of the mowing area
followed with the perimeter wire.
A freely travellable area with a minimum
width of 44 cm must be available to the
side of the floor plate (3).
If offset drive home (passage) is
used, the perimeter wire must be
routed at least
1.5 m
in front of and
behind the docking station in a
straight line and at right angles to
the floor plate. (
Further information on installation
of the external docking station is
contained in the "Installation
examples" section. (