21
Series 4144 Components FC, FS, KM
:
Squeeze the retaining tabs
(arrows) together and push the
stop switch (1) out of the support.
– Take the wires and stop switch
out of the support.
:
Pull the ground and short circuit
wires out of the guides (arrows).
545RA061 TG
1
545RA062 TG
:
Disconnect the short circuit wire
(1) and ground wire (2) from the
stop switch (3).
– Check the individual parts and
replace if necessary.
A faulty ground wire may impair or
prevent operation of the short circuit
wire. The ground wire must
therefore be tested for good contact
and continuity.
– Check operation of the stop
switch and replace it if necessary.
Installing
Ground and short circuit wires have
different lengths – position the short
circuit wire in the guides first.
– Lay the ground and short circuit
wires next to one another – do
not cross over.
545RA063 TG
3
1
2
545RA064 TG
1
2
– Push the flag terminals firmly on
to the connector tags of the stop
switch.
:
Push the flag terminal of the short
circuit wire (1) onto the rear
connector tag (see illustration).
:
Push the ground wire (2) onto the
connector tag.
The flag terminals must point to the
right with the switch in the position
shown (small arrow).
:
Pass the wires with stop switch
(1) through the opening (arrow).
:
Position the stop switch (2) so
that the lug (1) engages the slot
(arrow) in the support.
– Push the stop switch (2) into the
support until it snaps into
position.
545RA065 TG
1
545RA065 TG
2
1
Summary of Contents for FS 40
Page 1: ...STIH STIHL Series 4144 Components FC FS KM 2008 02 FS 40 FS 50 FS 56 FC 56 KM 56 ...
Page 79: ...78 Series 4144 Components FC FS KM ...
Page 80: ...79 Series 4144 Components FC FS KM ...
Page 81: ...80 Series 4144 Components FC FS KM ...
Page 82: ...englisch english 0455 545 0123 M7 E8 FST Printed in Germany ...