51
BR 500, BR 550, BR 600
Check “
#
“/“
0
“ function on
setting lever
or separate
stop switch
no
Install new
ignition module
yes
no
Look for fault in fuel system
or carburetor,
check engine for leaks,
check position of flywheel on
crankshaft
yes
Check operation
of setting lever
– Short circuit wire chafed?
– Contact gap (contact springs)
If necessary, install new ignition lead
and/or contact springs
Re-connect short circuit wire
2
3
Powerful
spark?
Engine
runs
RA_452_00_01_02.book Seite 51 Donnerstag, 16. Februar 2012 11:52 11