INSTRUCTION MANUAL   

 

GB

– 

4/5 

www.stifnet.com

 - DOC NO. BE0455061-A 

 

4)  Position  the  VIGIBELT

® 

TOUCH  detectors  on  the  openings  and  screw  the  M6  brake  nuts  with  the  washers 

(clamping torque 4 N.m) according to 

Figure-D.

 

 

5)  Connect the VIGIBELT

®

 TOUCH according to the electrical scheme E or F: 

NC detector = positive safety, permanent control of the proper functioning of the sensor  

Signal  loss  indicates  that there  is  a 

 strap offset problem 

 

 

 Electrical wire cut off 

 

 

3-wire/NC connection scheme E 

colours  
BN = Brown 
BU = Blue 
BK = Black 

PVC cable 3x0.11mm² 2m for ATEX zone and non-
ATEX  

3-wire connection scheme F 

Colours  
1 = Black 
2 = Grey 
4 = Blue 

PVC cable 2m for non ATEX 3x0.25mm² 

figure D 

Attach the VIGIBELT

®

 

Touch with

 

washers and lock nuts 

For low voltage sensor, ATEX or not 

3-wire cable connection 

L=2m cable  

Voltage 12-24V DC 

Voltage limits, including ripple, 10-36V DC 

Switching power 

 

100 mA 

temperature Operating: -25... 70°C (Non-ATEX) 

-20... 60°C (ATEX) 

Protection - IP67 

 Caution: Any connection must be made outside the 

ATEX zone 

For mechanical sensor, out of ATEX zone 

3-wire cable connection 

L=2m cable 

Tension 12… 250V AC/DC 

NC : Black wire (1) / Grey wire (2) 

NO : Black wire (1) / Blue wire (4) 

Operating temperature: -20... 105°C 

Protection - IP67 

 Caution: Any connection must be made outside the 

ATEX zone 
 
 