installation 

 

1)  Make two symmetrical round openings (opening Ø56mm + 4 holes Ø7 on Ø72) on each side on the riser of the 

elevator:   

 figure-A

 

 

 

 
 

 

Figure A 

On a bucket lift, position the VIGIBELT

®

 TOUCH 

detectors

 

on the rising leg side close to the axis of the 

pulleys and the strap. 

On a belt conveyor, position the VIGIBELT

®

 

TOUCH detectors side stretched strand close to the 
axis of the drums and the strip. 

Make an opening of 
Ø56 in the axis of the 
strap 

 
 strap 