6) After completing the mechanical and electrical installation of the VIGIBELT
®
TOUCH, you must proceed to the
verification of each detector to ensure that they are all operational. For this, you need to trigger each VIGIBELT
®
TOUCH by pressing their contact face. This simulation makes it possible to validate that the fault information is
communicated to the control system (M-JET monitoring, control plc, ...).
CONTROL & PERIODIC MAINTENANCE
1) To ensure the functional integrity of VIGIBELT
®
TOUCH, you must schedule periodic inspections. The frequency
of inspections must be sufficient to avoid dangerous situations (situations that affect the intrinsic functioning of the
VIGIBELT
®
TOUCH).
2) During these inspections, check that the VIGIBELT
®
TOUCH are not affected by the following defects: dust layer
>2mm, dust leak between the sheath of the elevator and the VIGIBELT
®
TOUCH, non-operational power supply
voltage, degraded electrical wiring, shocks on the envelope of the VIGIBELT
®
TOUCH, triggering of the detector with
a charge > 5 daN, etc...
3) In the case of one or more defects found, you must proceed with the restoration in order to correct the defect(s)
before you can use the bucket lift or belt conveyor again.
4) Only personnel trained and authorized in maintenance procedures for these equipment are able to carry out
inspections for VIGIBELT
®
TOUCH.
DISPOSAL
When dismantling the VIGIBELT
®
TOUCH, the user must ensure the proper disposal of this device and hand over
to the specialized harvesting centers the components according to their nature (stainless steel, electrical
equipment, seal, etc.).
In the event that the VIGIBELT
®
TOUCH kit is used, controlled, under conditions contrary to the precautions
described in this instruction manual, STIF declines all responsibility for damage caused to man, animal,
environment, material property.