OPeRATION
Menu
24
| WPM www.stiebel-eltron.com
PASTEURISATION PROGRAM
Note
For the PASTEURISATION PROGRAM, an emergency/
booster heater or external heat source must be connect-
ed.
In menu item PASTEURISATION PROGRAM, you can specify the
days and times at which the DHW cylinder heats the content to
the highest value.
START TIME
Here you can specify the start time at which the DHW cylinder
heats the content to the highest value.
f
f
Use the touch wheel to set the required start time. Confirm
your entry with “OK”.
Deleting the start time
f
f
Use the touch wheel to select the start time that you wish to
delete. Confirm with “OK”.
f
f
Use the touch wheel to reset the required start time to “--:--”.
Confirm your entry with “OK”.
DAYS
Here you can set the days on which the DHW cylinder heats the
content to the highest value.
f
f
Select the days on which you wish to specify heating of the
DHW cylinder. Confirm your entry with “OK”.
DHW CIRCULATION PROGRAM
Select DHW CIRCULATION PROGRAM to determine the times during
which the DHW circulation pump is controlled according to the
time program.
SWIMMING POOL PROGRAM
Select SWIMMING POOL PROGRAM to determine the times during
which swimming pool water heating should take place. Outside
those times, the swimming pool water heating will be switched
off.
Note
You can adjust the set value under SETTINGS / SWIMMING
POOL / SET TEMPERATURE.
SILENT PROGRAM 1
Select SILENT PROGRAM 1 to determine the times during which
the heat pump is offset to a reduced noise mode.
By reducing the fan speed, the noise level of the heat pump is
reduced. On certain heat pumps, the compressor power may also
be reduced. Your qualified contractor can inform you whether
both the fan speed and compressor output on your heat pump
can be reduced. Both of these options can be set by your qualified
contractor independently of one another.
SILENT PROGRAM 2
Note
When SILENT PROGRAM 2 is enabled, operating costs
will be higher.
Select SILENT PROGRAM 2 to determine the times during which
the heat pump is switched off. The internal emergency/booster
heater or external heat source takes over the heating and DHW
heating operations.
SETTINGS
Here you can change some of the settings. Your qualified contrac-
tor can set the other parameters for you.
GENERAL
TIME / DATE
SET SUMMER TIME
DAY BEGINNING
DAY ENDING
LANGUAGE
CONTRAST
BRIGHTNESS
HEATING
HEATING CIRCUIT 1
COMFORT TEMPERATURE
ECO TEMPERATURE
HEATING CIRCUIT 2
COMFORT TEMPERATURE
ECO TEMPERATURE
HEATING CIRCUIT 3
COMFORT TEMPERATURE
ECO TEMPERATURE
HEATING CIRCUIT 4
COMFORT TEMPERATURE
ECO TEMPERATURE
HEATING CIRCUIT 5
COMFORT TEMPERATURE
ECO TEMPERATURE
DHW
DHW TEMPERATURES 1
COMFORT TEMPERATURE
ECO TEMPERATURE
DHW TEMPERATURES 2
COMFORT TEMPERATURE
ECO TEMPERATURE
COOLING
GENERAL
TIME / DATE
Select TIME / DATE to set the current time, year, month and day.
f
f
Use the Touch-Wheel to select the field you want to change.
Confirm the selection with OK.
f
f
Use the Touch-Wheel to set the day, the month, the year or