www.stiebel-eltron.com
WPC | WPC cool |
43
installation
troubleshooting
16.3 resetting the high limit safety cut-out
If the heating water temperature exceeds 95 °C, the electric emer-
gency/booster heater shuts down.
2
1
D
00000
37
50
4
1 Electric emergency/booster heater
2 High limit safety cut-out reset button
f
f
Remove the cause of the fault.
f
f
Reset the high limit safety cut-out by pressing the reset but-
ton. To do so, use a pointed object.
f
f
Check whether the heating water is being circulated at a suf-
ficiently high flow rate.
16.4 resetting the compressor high limit safety cut-
out
If the hot gas temperature exceeds 140 °C, the compressor shuts
down.
D
00000
37
51
1
1
1 High limit safety cut-out reset button
f
f
Isolate the appliance from the power supply.
f
f
Remove the cause of the fault.
f
f
Reset the high limit safety cut-out by pressing the reset
button.