13.3.7 emerGency opr
Characteristics when "Fatal Error" fault occurs in conjunction with
emergency operation:
The EMERGENCY OPR parameter can be set to ON or OFF.
Emergency operation set to ON:
The program selector automatically changes over to emergency
mode as soon as faults occur and the heat pump fails.
Emergency operation set to OFF:
As soon as faults occur and the heat pump fails, the electric emer-
gency/booster heater takes over the frost protection of the central
heating system. Users can then independently select emergency
mode.
13.3.8 Heat pump reSet
If a fault occurs the heat pump can be reset. Setting it to ON resets
the fault that has occurred. The compressor starts again. The fault
remains stored in the fault list.
13.3.9 fault liSt reSet
ON / OFF
The entire fault list is deleted.
13.3.10 SyStem reSet
A system reset will reset the heat pump manager to its delivered
condition (factory settings).
f
f
You will need to select the corresponding heat pump type
again.
Please read carefully
The heat pump can only be operated as a ground source
heat pump.
f
f
Heat pump type WPC MFG must be set.