oPeration
menu structure
www.stiebel-eltron.com
WPC | WPC cool |
15
COOLING
COOLING
ON / OFF
COOLING MODE
PASSIVE COOLING / ACTIVE COOLING
ACTIVE COOLING
AREA COOLING
SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
DYNAMIC
FAN COOLING
SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
DYNAMIC
PASSIVE COOLING
AREA COOLING
SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
FAN COOLING
SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
5.4.1 General
time / date
Here you can set the time, year, month and day.
SettinG Summer time
Here you can adjust the settings for summer time.
Summer time is factory set to begin on 25 March and to end on
25 October.
contraSt
Here you can adjust the display contrast.
BriGHtneSS
Here you can adjust the display brightness.
toucH SenSitivity and toucH acceleration
A code is required for this adjustment.
5.4.2 HeatinG
Heat circuit 1 and Heat circuit 2
Set room temp comfort and Set room temp eco
Here you can select the set room temperatures for comfort mode
and ECO mode as well as the heating curve rise for heating circuit 1
and heating circuit 2.
Changing the set room temperature results in a parallel shift of
the heating curve.
As soon as the FE 7 remote control has been connected and allo-
cated to heating circuit 1, the actual room temperature can also
be scanned.
As soon as the FE 7 or FEK remote control has been connected
and allocated to heating circuit 2, the actual room temperature
can also be scanned.
The display HEAT CIRCUIT 2 only appears if the mixer flow sensor
for heating circuit 2 has been connected.
HeatinG curve riSe
The menu item HEATING CURVE RISE enables you to set one heat-
ing curve each for heating circuits 1 and 2.
Note: Your contractor will have set a building and system-specific
optimum heating curve for every heating circuit. For heating cir-
cuit 1 the curve relates to the heat pump return temperature, for
heating circuit 2 to the mixer flow temperature.
When you adjust the heating curve on the heat pump manager, the
calculated set return or flow temperature, subject to the outside
temperature and the set room temperature, will be shown at the
top of the display.
As soon as you have preselected a temperature in menu SETTINGS
/ HEATING / STANDARD SETTING under parameter FIXED VALUE
OPERATION, heating curve 1 is hidden from view and the display
showsSET FIXED TEMPERATURE with the relevant temperature.