13. Troubleshooting
Note
At temperatures below -15 °C the high limit safety cut-out
may respond. The appliance may be subjected to these
temperatures during storage or transport.
Fault
Cause
Remedy
The water does not heat
up and the ON/OFF indi-
cator does not illuminate.
The high limit safety
cut-out has responded
because the controller is
faulty.
Remedy the cause of the
fault. Replace the con-
troller.
The high limit safety
cut-out has responded
because the temperature
has fallen below -15 °C.
Press the reset button
(see diagram).
The water does not heat
up and the ON/OFF indi-
cator illuminates.
The flanged immersion
heater is faulty.
Replace the flanged im-
mersion heater.
The water does not heat
up sufficiently and the
ON/OFF indicator illumi-
nates.
The temperature control-
ler is faulty.
Replace the temperature
controller.
The safety valve drips
when heating is switched
off.
The valve seat is contam-
inated.
Clean the valve seat.
Immersion heater accessory: Reset button for high limit safety
cut-out
The reset button is located behind the temperature selector.
f
f
Pull off the temperature selector.
1
D
00000
48
184
1 Reset button for high limit safety cut-out
14. Maintenance
For some maintenance work you must remove the lower cover.
If you need to drain the appliance, observe chapter "Draining the
appliance".
Note the insertion depths of the controller-limiter combination
(see chapter "Specification / Dimensions and connections").
Immersion heater accessory:
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.
14.1 Checking the safety valve
f
f
Check the safety valve regularly.
14.2 Draining the appliance
WARNING Burns
Hot water may escape during draining.
Note
For filling, venting and draining the system, open the
non-return valves of the compact heat pump installations.
f
f
Turn the adjusting screws of the compact heat pump
installations so that the slot is aligned with the di-
rection of flow. The adjusting screw of the WPKI-H
non-return valve is located behind the thermometer.
f
f
After filling, venting or draining the system, turn the
adjusting screws again through 90°.
If the appliance needs to be drained for maintenance or to protect
the whole installation when there is a risk of frost, proceed as
follows:
D
00000
48
08
2
1
1 Drain valve
f
f
Drain the appliance using the drain valve.