13.56 MHz Legic® 
Upgradable readers ARC 
Installation instructions 

 

 
13,56 MHz Legic® 
Lecteurs évolutifs ARC 
Notice d’installation

 

 
13.56 MHz Legic® 
Lectores escalables ARC

 

Procedimiento de instalación

  

conforme con

 NOM-024 -SCFI-2013

 

 

 

© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1101C05 - Page 

2

 sur 

12 

-

 

Ed. 06/06/2019 

 

 

Precautions for installation 

  The s

upply voltage at the reader’s connector should be b7 Vdc and +28 Vdc. 

  As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level 

and the proximity of the reader. 

  Recommended distance between two readers: parallel plane: 11.8 in 

– same plane: 15.8 in – perpendicular plane: 9.8 in.

 

 

  Readers installed on a metal surface may have reduced performances. 

  Use a ferrite (two-way) for the cable (power supply and data). 

Example: reference 74271222 WURTH ELEKTRONIK

  By design, the reader can be installed indoors and outdoors. 

 

Disconnect the wires or the connector of the reader BEFORE powering on or off

  Operating temperature:   

Readers L, M, N: -4 °F to 158 °F / -20°C to +70°C 
Readers O, P, Q: -14 °F to 122 °F / -10°C to +50°C 

 

TTL pull-ups 

For data signals, 10k

 pull-up resistors are connected internally to V

in 

(power supply voltage) for optimal wiring distances. 

 

RS232 / RS485 communication 

 
 
 
 
 
 
 
 
 
 

Bus architecture (RS485) 

Wiring resistors R1 and R2 use extended features of the RS485 bus: FAIL-SAFE (see RS485-AN-960). 
R1 & R2: 1.5 k

Ω resistor not supplied. 

R

T

120 Ω end-of-line resistor supplied 

 
 
 
 
 
 
 
 
 
 
 

Smart mounting plate dimensions 

 
Version 1   

 

 

 

 

 

 

Version 2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
General tolerance following ISO NFT 58-000 standard. 

 

Scalability 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

UTL 

L+ 

 

  

L- 

L+      L-

 

ARC 

ARC 

ARC 

Scalability  is  a  specific  feature  of  the  Architect® 
series.  Each  reader  is  composed  of  three  parts:  one 
switchable  cover,  one  RFID  core  and  one  smart 
mounting  plate.  You  can  upgrade  functionalities  and 
security levels by switching the cover and/or adding a 
biometric module. 

Baud rate

 

9600, 19200, 38400, 57600, 115200 bauds 

Default Baud rate 

ARC R: 9600; ARC W: 38400 (SSCP),  

Mode

 

Asynchronous 

Number of bits

 

Transfer mode

 

LSB first 

Stop bit

 

RS485

 

Default broadcast address 00h 

 

US 

FR 

ES 

More  details  about  reader 
communication are available 
in the protocol specification

 

Summary of Contents for Architect LEGIC ARC Le2 Series

Page 1: ...Installation instructions Notice d installation Procedimiento de instalaci n LEGIC...

Page 2: ...ader will perform the operations configured with the SSCP protocol Caution switch on the reader when it is in its final position to initialize the accelerometer in the correct position Relay Read only...

Page 3: ...reader BEFORE powering on or off Operating temperature Readers L M N 4 F to 158 F 20 C to 70 C Readers O P Q 14 F to 122 F 10 C to 50 C TTL pull ups For data signals 10k pull up resistors are connecte...

Page 4: ...clips Disconnect the flat flexible antenna cable from connector J6 Remove the core from the front part steps 1 2 Install the core in the keyboard front part Connect the flat flexible antenna cable to...

Page 5: ...This device complies with the safety requirements for RF exposure in accordance with RSS 102 issue 5 for conditions of use DEEE Pro Member In accordance with the provisions of the Environment Code STi...

Page 6: ...finale pour initialiser l acc l rom tre dans la position correcte Relai Lecteur en lecture seule sauf cran tactile gestion automatique de l arrachement Lecteur cran tactile lecture seule si la fonctio...

Page 7: ...rature ambiante de fonctionnement Lecteurs L M N 20 C 70 C Lecteurs O P et Q 10 C 50 C C blage des pulls ups en TTL Pour les signaux de donn es des r sistances de pulls up de 10k au Vin tension d alim...

Page 8: ...la fa ade Puis faire pivoter la carte et l ins rer en force entre les 2 clips D connecter la nappe d antenne du connecteur J6 Retirer le c ur de la fa ade tapes 1 2 Installer le c ur dans la fa ade c...

Page 9: ...t pour l exposition aux RF en conformit avec RSS 102 issue 5 pour les conditions d utilisation Adh rent DEEE Pro Conform ment aux dispositions du code de l environnement Sous section 1 Paragraphe 1 ar...

Page 10: ...u posici n final para activar el aceler metro en la posici n correcta Rel Lector de solo lectura excepto pantalla t ctil gesti n autom tica de extracci n Lector de pantalla t ctil de solo lectura si l...

Page 11: ...tores L M N 20 C a 70 C Lectores O P Q 10 C a 50 C Cableado de pull ups en TTL Para las se ales de datos las resistencias pull up de 10k en Vin tensi n de alimentaci n del lector est n pre equipadas e...

Page 12: ...l frontal Despu s gire la placa e ins rtela a presi n entre los dos clips Desconecte el cable de la antena del conector J6 Retire el n cleo del panel frontal Pasos 1 2 Instale el n cleo en la parte fr...

Page 13: ...de seguridad de exposici n a radiaciones de frecuencia conforme a las reglas RSS 102 edici n 5 para las condiciones de operaci n Miembro DEEE Pro De acuerdo con las disposiciones del C digo de Medio...

Reviews: