13.56 MHz Legic®
Upgradable readers ARC
Installation instructions
13,56 MHz Legic®
Lecteurs évolutifs ARC
Notice d’installation
13.56 MHz Legic®
Lectores escalables ARC
Procedimiento de instalación
conforme con
NOM-024 -SCFI-2013
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1101C05 - Page
1
sur
12
-
Ed. 06/06/2019
Product references
Power supply characteristics
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC EN 60950-1 Ed2) or type ES1, PS1 (according to IEC EN 62368-1) for the main supply.
Main power supply: Range: +7 Vdc to +28 Vdc
Typical: 12 Vdc
Max. consumption at 12 Vdc:
ARC-L: 130 mA / ARC-M: 160 mA / ARC-N: 200 mA / ARC-O: 280 mA / ARC-P: 310 mA / ARC-Q: 350 mA
Characteristics
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock and Data)
Connection:
Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch
Protection:
IP65, excluding connectors
Static relay:
ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1
Ω typical for AC/DC
Recommended cables
Use a multi-conductor shielded twisted pair cable.
Max. length RS485: 328.1 ft at 9600 baud
Max. length RS232: 49.2 ft
Wiegand / Clock & Data:
1 pair AWG24
– 98.4 ft max / 2 pairs AWG24 – 196.9 ft max / 3 pairs AWG24 – 328.1 ft max
1 pair AWG20
– 164.0 ft max / 2 pairs AWG20 – 328.1 ft max
Buzzer / LED
The operating mode for the Buzzer and LED 1 and 2 can be programmed by configuration (R3x) or controlled by the remote system with a 0 Vdc respectively on
the
“
Led 1
”, “
Led 2
” and “
Buzzer
” inputs of the reader’s connector or controlled by the communication protocol of the reader (W3x).
Anti-tearing
Tearing is detected by an accelerometer
. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of
reader.
▪
for R31 reader: the wrenching signal will be
emitted on the “Data/Data1” line. This function is configurable via configuration.
▪
for W32 and 33: the reader will perform the operations configured with the SSCP protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Relay
Read-only reader, except touch screen: automatic tamper management.
Touch screen read-only reader: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read/Write reader: the relay is controlled by the SSCP protocol commands.
Read-only reader configuration
R readers are configurable by serial link for non-secure paramete
rs and by master card SAM to access secure data on user’s card.
Reader retrieve configuration from SAM at any time.
- If the SAM is accepted, LED lights green, maintain the SAM in front of the reader until the buzzer beeps 5 times.
- If the SAM is not accepted, LED lights red and buzzer is activated 1s.
Powering-up the readers
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial ARC only: the orange LED flashes 20 times: waiting for an update.
4. Activation of the default LED (flashes blue if no customer specific configuration).
5. ARC Screen: display of the default image.
Precautions for the biometric sensor and keypad
▪
For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
▪
The keypad is sensitive. Take off your gloves to enter your code.
▪
For the ARC screen with an activated keypad, the default mode is: display the keyboard
.
ARC-X-Le2
X:
L: Standard
M: Keypad
N: Touch screen
O: St Biometrics
P: Biometrics
Q: Touch Biometrics
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
Connector
Type
J4
Wiegand
Clock & Data
RS232
RS485
1
0 Vdc
2
+Vcc (+7 Vdc to +28 Vdc)
3
D0
Code
NC
NC
4
D1
Data
NC
NC
5
Clock
Clock
NC
NC
6
NC
NC
Tx
L+
7
NC
NC
Rx
L-
8
Led 1
9
Led 2
10
Buzzer
US
FR