background image

DIMENSIONS

3

SPECIFICATIONS

OPERATING VOLTAGE

Internal power 9 VDC battery (not included)
Remote power 12-30  VDC

OPERATING TEMPERATURE

32°F -120°

POWER CONSUMPTION

Stand by: 50µA
Siren low volume: 85mA
Siren high volume: 90mA
Strobe: 25mA

SIREN VOLUME

Low: 85 dB
High: 100 dB

ALARM TIMING

Independent control for siren and strobe:
15s, 30s, 60s, continuous

LOW BATTERY WARNING

LED flash once every 30 seconds

FORM C DRY CONTACTS

0-30VAC/DC, 1 Amp

RATED FOR

Contacts reset after longest alarm setting

KEY SWITCH

Alarm on: normally closed

ALARM SWITCH

Stand by: normally open contact required

POLYCARBONATE

UL94V-2

FLAMMABILITY RATING

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14.2 in.

(360mm)

12.2 in.

(310mm)

 BOTTOM VIEW

FRONT VIEW

6.44 in.

(164mm)

23.5 in.

(597mm)

16.5 in.

(419mm)

 

 

1/4”

DIAMETER

Summary of Contents for STI-7534

Page 1: ...ng tabs or internal drill dimples Cover includes a coated steel internal mounting plate with a baked on white enamel finish Siren strobe alarm lens is red Also available with amber green blue or white lens Siren offers 32 user selectable tones Alarm can be set for a piercing 100 dB or 85 dB Independent strobe and siren timing of 15 seconds 30 seconds 60 seconds or continuous Powered by a 9 VDC bat...

Page 2: ...will need to periodically test the connections to make sure audibles function at a sound level to alert staff Installer may need to purchase a simple audio meter typically available at your local electronics store to measure the sound in areas where the alarm is expected to be heard during normal noise environment Results from this test may prove it beneficial to purchase additional siren strobe a...

Page 3: ...00 dB ALARM TIMING Independent control for siren and strobe 15s 30s 60s continuous LOW BATTERY WARNING LED flash once every 30 seconds FORM C DRY CONTACTS 0 30VAC DC 1 Amp RATED FOR Contacts reset after longest alarm setting KEY SWITCH Alarm on normally closed ALARM SWITCH Stand by normally open contact required POLYCARBONATE UL94V 2 FLAMMABILITY RATING 14 2 in 360mm 12 2 in 310mm BOTTOM VIEW FRON...

Page 4: ...lecting a suitable location place cabinet in closed position against the wall Mark and drill 4 1 4 in diameter holes Insert the 4 19033 anchors Mount cabinet by driving in the four 10 x 1 1 2 in screws 3 For STI 7531AED select one of the two shelf mounting locations install shelf Close and lock cabinet 19033 ANCHOR 4 PROVIDED 04875 MOUNTING PLATE PROVIDED 19002 SCREW 8 32 x 3 8 in 4 PROVIDED OPTIO...

Page 5: ...US FAST 1 ALARM TIMING VOLUME STROBE TIMING ON OFF 1 2 3 4 5 0 15 seconds 1 1 1 1 High 30 seconds 1 0 1 0 1 60 seconds 0 1 0 1 Low Continuous 0 0 0 0 0 1 ON 0 OFF STEP 3 ALARM TONES S1 STEP 4 ALARM TIMING AND VOLUME S2 S1 ALARM TONE S2 ALARM TIMING STROBE TIMING VOLUME LED QTY 10 LOW BATTERY INDICATOR LED TERMINAL STRIP TAMPER SWITCH REAR VIEW WIRE ENTRY BATTERY BATTERY CABLE SIREN O 1 2 3 4 5 1 2...

Page 6: ... behind circuit board mounting plate Rotate lens into position Secure with tamperproof screw and special wrench Unit will not operate properly if lens cover is not installed STEP 6 TERMINAL STRIP CONNECTIONS REMOTE POWER IN 12 24 VDC 125mA OPTIONAL OFF ON MAIN POWER CONTROL TO KEY SWITCH STAND BY REED SWITCH FROM CABINET FORM C DRY CONTACTS NORMALLY OPEN COM DC IN KEY SWITCH ALARM SWITCH NC COM NO...

Page 7: ...ronics assembly 1 05050 R Red lens unless otherwise specified 1 09723 Key switch mounting bracket 2 18075 801 key 1 18074 Switch lock 1 18151 N C reed switch and magnet installed in cabinet 4 19002 Screw 8 32 x 3 8 in 2 19039 Screw 6 x 1 1 4 in 2 19018 Anchor 8 10 1 19011 8 32 x 1 2 in tamper screw 1 19016 Tamper wrench 1 BAT 9VDC 9 volt battery SIREN STROBE ALARM CABINET 1 07530 Hinged polycarbon...

Page 8: ...e Redditch Worcestershire B98 0HU England Tel 44 0 1527 520 999 Fax 44 0 1527 501 999 Freephone 0800 085 1678 UK only E mail info sti europe com Web www sti europe com ACCESSORIES AND REPLACEMENT PARTS AED LBL AED label 2 included applied to sides of cabinet must be factory installed STI SA5000 R Replacement Siren Strobe Alarm 18054 Replacement key for cabinet lock on STI 7534 18075 Replacement ke...