5
1
0 0 0 0 0
BUZZ
2
1 0 0 0 0
SLOW ON/OFF
3
0 1 0 0 0
SLOW SIREN
4
1 1 0 0 0
3 BEEP/PAUSE/REPEAT
5
0 0 1 0 0
UFO FAST
6
1 0 1 0 0
FAST SIREN
7
0 1 1 0 0
#5 FAST
8
1 1 1 0 0
#2 MEDIUM
9
0 0 0 1 0
#5 MEDIUM
10
1 0 0 1 0
SWOOP MEDIUM
11
0 1 0 1 0
#3 MEDIUM
12
1 1 0 1 0
BUZZ TONE
13
0 0 1 1 0
STEADY FAST
14
1 0 1 1 0
SWOOP SLOW
15
0 1 1 1 0
CONTINUOUS
16
1 1 1 1 0
FAST REPEAT
17
0 0 0 01
STANDARD ALARM
18
1 0 0 0 1
#3 FAST
19
0 1 0 0 1
#5 SLOW
20
1 1 0 0 1
FAST BEEP
21
0 0 1 0 1
SOUND A
22
1 0 1 0 1
SOUND B
23
0 1 1 0 1
SOUND C
24
1 1 1 0 1
SOUND D
25
0 0 0 1 1
SOUND D LOUD
26
1 0 0 1 1
SOUND E
27
0 1 0 1 1
SOUND F
28
1 1 0 1 1
SOUND G
29
0 0 1 1 1
SOUND H
30
1 0 1 1 1
#4 LOW
31
0 1 1 1 1
SOUND K
32
1 1 1 1 1
CONTINUOUS FAST
1
ALARM TIMING
VOLUME
STROBE TIMING
ON
OFF
1
2
3
4
5
0
15 seconds
1
1
1
1
High
30 seconds
1
0
1
0
1
60 seconds
0
1
0
1
Low
Continuous
0
0
0
0
0
1 = ON
0 = OFF
STEP 3 - ALARM TONES - S1
STEP 4 - ALARM TIMING AND VOLUME - S2
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
O
O
1 2 3 4 5
1 2 3 4 5
ALARM
TIMING
1 2
3 4
5
VOLUME
STROBE
SIREN
*
Factory default settings
*
*
STEP 2 - ELECTRONIC SETUP -
SELECT ALARM TONE AND TIMING SEQUENCE
NOTE:
Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
NOTE:
Sound may be disabled by clipping
wires to the siren. THIS WILL VOID ALL
WARRANTIES. Remove two screws on
circuit board; leave enough length of
wire to possibly reattach in the future.
Then insulate wires to prevent shorting
to electronic components.
O
WIRES TO SIREN